Freestanding Venting Options; External Venting - Fisher & Paykel DE4560M Installation Instructions Manual

Hide thumbs Also See for DE4560M:
Table of Contents

Advertisement

Freestanding
The dryer stands on the floor and can easily be moved into position.
1. Move the dryer into the desired position. Do not lift the dryer
by the top panel.
2. Have a minimum clearance on all sides of at least 20mm.
3. Have a minimum clearance at the rear of 75mm. The
spacers from the accessory wall mounting kit can be used to
set this distance.
4. Install the dryer on a stable and level floor.

Freestanding Venting Options

The vent system should be less than
two metres long with no more than three
90⁰ bends.
Before a rear venting option is installed the dryer must be changed
from the front venting factory setup. Remove the outlet grille from the
front left-hand side and replace with the outlet cover from the rear left-
hand side. These covers should be gently pried at the sides to
prevent damage.

External Venting

The dryer is vented with a kit that can be positioned to remove air to
the side.
The dryer is vented directly through the wall using a ducting kit in
combination with the duct adaptor supplied with the dryer.
The dryer is vented through a window using a ducting kit in
combination with the duct adaptor supplied with the dryer. This
requires the dryer to be a minimum distance of 140mm from the wall
https://producthelp.fisherpaykel.com/au/Dry/Dryers/Vented/DE4560M1/User_Guide_DE4560M1/03_Installation_Instructions
External venting with kit part number
PD-DK4W
External venting with kit part number
PD-SVHCW4