10.3.3 Error Detection

A parity error, framing error, and overrun error are detected.
stored in the buffer as "?".
(1) Framing error
This error results when a space is detected in detecting the stop bit.
as "?".
(2) Parity error
If a parity check has been specified and an error is detected at the time of parity check, that data is
stored in the buffer as "?".
(3) Overrun error
If an overrun error is detected, that data is stored in the buffer as "?".

10.3.4 Data Receiving Control

When the DTR signal is a space, the data from the host side can be received.
the data cannot be received.

10.3.5 Buffering

The DTR and TXD signals are available as control signals to transfer the data to the input buffer.
When an error is detected, that data is
36
iDP3420/3421/3423 User's Manual
That data is stored in the buffer
When it is a mark, however,