7. Drawer Kickout Connector
7.1 Specifications
(1) Drawer-Kick Drive Signal
Pulses specified by ESCp are output. Also, SW(+) state, in parallel interface, can be
observed by Pin 34 of the interface connector and, in serial interface, by ESC u command.
(2) Electrical Characteristics
1) Drive voltage
2) Drive current
3) SW signal
7.2 Connector's Pin Configurations
No.
1
2
3
4
5
6
Caution
1)
No output is available during printing.
2)
Drawer 1 and Drawer 2 can not be driven simultaneously.
3)
Use a solenoid of 36 Ohm or more for the drawer. Do not exceed 0.8A for output current.
Failure or seizure can take place.
4)
No connection is available to a to a telephone line.
7.3 Drive Circuit
CITIZEN
:
DC24V
:
Max. 0.8A (within 510ms)
:
signal level "L"= 0 - 0.5V
SIGNAL NAME
FG
DRAWER 1
DRSW
VDR
DRAWER 2
GND
Connector used
Applicable connector : TM3P-66P (Hirose) or equivalent
"H"= 3 - 5V
FUNCTION
Frame ground
Drawer 1 driving signal
Drawer SW input
Drawer driving power supply
Drawer 2 driving signal
Common ground on the circuits
: TM5RJ3-66 (Hirose) or equivalent
43