LUBRICATOR: Designed to operate at 250 PSI max pressure and a temperature range
of 40°F to 160°F. This simple, trouble-free design has a large capacity Metal Bowl w/
Sight Glass. It can be filled to the top to extend intervals between filling and the Sight
Glass makes it easy to monitor oil levels. The Lubricator is always installed downstream
of the Filter and the Regulator. It automatically maintains the proper air to oil ratio
regardless of variation in air flow. While the Lubricator must be initially filled while the
Service Unit is not pressurized, the Lubricator can be refilled under pressure by slowly
removing the Filler Plug to release back pressure and then inserting a long spout/funnel
into the opening and adding oil until the Metal Bowl is filled (Sight Glass).
Metal Bowl must not be removed while the Service Unit is under air supply
pressure.
NB:
Check the Lubricator's oil level Sight Glass daily, and add Tool-Lube Air
Motor Oil as required.
The Lubricator automatically varies oil mist delivery with air flow variations at any
adjustment. The Lubricator's Wick Element Assembly is factory pre-set at a "mean"
(halfway) adjustment that is appropriate for most Gate Opener applications (distance
between the FRL and the Gate Opener can affect oil mist delivery). If necessary,
increased oil mist delivery can be obtained by raising the Oil Feeder Wick (A) (see
Figure 6) higher in the verturi (air stream). To decrease oil mist delivery, lower the Oil
Feeder Wick into the venturi. Read following instructions if oil mist delivery must be
changed.
IMPORTANT
IMPORTANT
The Lubricator for the GO-A8-PW is empty
when shipped from the factory. To avoid
damage to the Impactor the Lubricator must be
filled prior to operation.
WORKMASTER's TOOL-LUBE Air Tool Oil is
recommended. It is a High-Grade Air Tool Oil with
absorbing emulsifiers.
following: Kerosene, hydraulic fluid, transmission
fluid, spindle oil, motor oil or antifreeze.
For cold weather operation, such as winter
conditions (below 40° F), when the GO-A8-PW is
used outdoors or in an un-heated service area, the
Lubricator should be filled with a Winter Grade Air
Tool Oil (PN: 40007).
PH: 866.476.9217
Do Not Use
any of the
NB: The
13
Need help?
Do you have a question about the GO-A8-PW and is the answer not in the manual?
Questions and answers