Fig. 66 Draining The Cooling Oil (Closed Floor Pan - Stationary Machine) - KAESER M100 Operator's Manual

Screw compressor
Table of Contents

Advertisement

Option oe, rw, rx
Fig. 66
Further information
136
10
Maintenance
10.4
Compressor Maintenance
Draining the cooling oil (closed floor pan - stationary machine)
Oil separator tank
1
Oil filler plug
2
Oil cooler
3
Shut-off ball valve
4/5
I – open
0 – closed
➤ Remove the plug
from the oil separator tank filling port.
2
Draining the oil from the separator tank
1. Position a receptacle beneath the oil drainage point for the oil separator tank's cooling oil
2. Unscrew the corresponding screwed sealing cap at the cooling oil drain.
3. Open the shut-off valve
4. Close the shut-off valve and replace the screwed sealing cap.
Draining the oil from the oil cooler
1. Position a receptacle beneath the oil drainage point for the oil cooler's cooling oil
2. Unscrew the corresponding screwed sealing cap at the cooling oil drain.
3. Open the shut-off valve
4. Close the shut-off valve and replace the screwed sealing cap.
Perform final work steps:
1. Replace the plug
in the oil separator tank filling port.
2
2. Close the door.
Dispose of used oil and oil-contaminated working materials according to environmental pro‐
tection regulations.
See chapter 10.4.2 for oil filling.
Operator Manual
Screw Compressor
M100
6
7
8
at the oil separator tank and catch any draining cooling oil.
5
at the oil cooler and catch any draining cooling oil.
4
Screwed sealing cap - cooling oil drain
Oil cooler drain
Oil separator tank drain
.
8
.
7
No.: 9_6999 23 USE