To prevent the build up of condensation produced by your DishDrawer™ Dishwasher, the external venting kit must be installed via one of the following options:
THROUGH SAME CABINET
FRAMELESS
3/16"
Ø2 1/4"
7 7/8"
3 15/16"
custom framed edge
ISO*
A toe kick height of at least 3 15/16" (100mm) is required.
z
A Ø2 1/4" (Ø57mm) service hole should be created
z
through the side wall following the guidance under
'Cabinetry preparation'. In addition to this, a second
Ø2 1/4" (Ø57mm) service hole must be also be created
through the shelf and the base of the cavity to route the
venting hose through.
Frameless cabinetry: A 3 15/16 – 7 7/8" (100mm x 200mm)
z
cutout must be created at the front of the cabinetry base
to secure the duct to.
Framed cabinetry: A toe kick depth of at least 2 3/8"
z
(60mm) is required. In addition, a 3 15/16 – 7 7/8"
(100mm x 200mm) cutout must be created within the
adjacent cabinetry base to secure the duct to. This cutout
should be set back a minimum of 1" (25mm) from the
frame edge for optimal venting.
14
EXTERNAL VENTING PREPARATION
THROUGH ADJACENT CABINET
FRAMED
FRAMELESS
3/16"
Ø2 1/4"
7 7/8"
1"
3 15/16"
A toe kick height of at least 100mm is required.
z
A notched-out Ø2 1/4" (Ø57mm) service hole should
z
be created through the side wall following the
guidance under 'Cabinetry preparation'.
Frameless cabinetry: A 3 15/16 – 7 7/8" (100mm x
z
200mm) cutout must be created in the base of the
adjacent cabinetry to secure the duct to.
Framed cabinetry: A toe kick depth of at least 2 3/8"
z
(60mm) is required. In addition, a 3 15/16 – 7 7/8"
(100mm x 200mm) cutout must be created within the
adjacent cabinetry base to secure the duct to. This
cutout should be set back a minimum of 1" (25mm)
from the frame edge for optimal venting.
*Frameless install illustrated
FRAMED
3/16"
3/16"
Ø2 1/4"
Ø2 1/4"
7 7/8"
3 15/16"
3 15/16"
custom framed edge
ISO*
*Frameless install illustrated
THROUGH FLOOR
7 7/8"
1"
There is no minimum toe kick height for venting the
z
DishDrawer™ Dishwasher through the floor below the
cabinetry, the space below the floor however, must be a
sub-area of the house and have adequate airflow.
A Ø2 1/4" (Ø57mm) service hole should be created
z
through the side wall following the guidance under
'Cabinetry preparation'. In addition to this, a Ø2 1/4"
(Ø57mm) service hole must be also be created through
the shelf, the base of the cavity and the floor to route the
venting hose through.
The duct is not required for this venting method.
z
Ensure all cutout edges are smooth and rounded and the
z
supplied edge protector is fitted if required.
Ensure cutout in the floor is sealed adequately.
z
FRAMED & FRAMELESS
3/16"
Ø2 1/4"
ISO