Refrigeration; Controls And Adjustments; Self Contained Models - Hussmann DDS Installation And Service Instructions Manual

Self-contained and remote multi-deck, spot display refrigerator merchandisers
Hide thumbs Also See for DDS:
Table of Contents

Advertisement

07/02/03

REFRIGERATION

Each self-contained model is equipped with its own condensing unit located beneath the display
area. The unit will be charged per nameplate refrigerant and shipped from the factory with all
service valves open, completely ready for operation when electrical power has been connected.
REFRIGERANT CHARGE
MODEL
DDS/DDF-4B
DDS/DDF-4D/G
DDS/DDF-6D/G
DDS/DDF-8D/G
DDS – 4D/G c/w
Hp Condensing Unit
DDSS – 4D/G

CONTROLS and ADJUSTMENTS

REFRIGERATION
CONTROLS
DISCHARGE AIR
TEMPERATURE
28 to 34 F
A refrigeration thermostat controls refrigeration temperature. The control is factory
installed in the control panel. Adjust this thermostat to maintain the discharge air
temperature shown. Measure discharge air temperatures at the center of the discharge
honeycomb.
Defrosts are time-initiated and pressure terminated. The defrost timer is factory set as
shown. Check that the above settings are implemented and correct, and that the clock
indicated the correct time of day.
Defrost must be terminated by defrost termination setting.
HUSSMANN - GLOVERSVILLE
SECTION 3

SELF CONTAINED MODELS

-
REFRIGERANT
R - 22
R - 22
R - 22
R – 404A
R - 22
R-22
DEFROST CONTROLS
DEFROST
FREQUENCY
Every
6 Hours
POUNDS
5
5
7
8
5
5
PRESSURE
TERMINATION
90 psig (R-22)
105 psig (R-404A)
Page 5
OUNCES
8
8
11
2
0
8
FAILSAFE
45
Minutes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddss

Table of Contents