4.8. Condensate drainage

Automatic drain system
st
The system consists of four electronically controlled condensate drains, which are installed one after the 1
stage,
nd
rd
th
one after the 2
stage, one after the 3
stage and one after the final 4
stage separator. The drains are controlled
electronically and open automatically via the digital controller.
Note 1: In case of emergency (damaged auto drain system), the user may use the four (4) alternative manual
drains.
Note 2: Condensate color is milky-white. If condensate suddenly changes color or start smelling, this is indication of
oil presence. Immediately check:
1. oil quality
2. oil level
3. filters' condition and especially the condition of BA filter cartidges
4. air inlet filter's condition
5. piston rings and cylinders condition
Note 3: Always empty the condensate collecting tank (1) when the level reaches the maximum allowed (2).
th
Note 4: BA Filter base is equipped with an extra manual drain, 5
drain. Use this drain only to check the status of
BA filter housing/cartridges. Open this drain every 5 continuous working hours and after compressor shut down.
Auto drains
(4pcs)
1
Manual drains
(4pcs)
2