5. Electronic Controller

5.1. General Operation

5.1.1. Semi Automatic Mode (Standard Configuration)

Semi Automatic mode can be set in Operation Menu P01 after entering the user level access code. Semi Automatic
is a mode of operation in which the operator has control of when the compressor runs. The operator starts the
compressor by pressing the start button. When the pressure is below the unload pressure, the motor is started
immediately and the pressure will rise. The compressor will achieve the set unload pressure and then stop. The
compressor will only start again if the operator presses the start button again. In any case, the compressor stops
immediately when pressing the stop button.
Motor
Pressure
Stop
Start Button
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
1-2018 edition
High
Motor
Pressure
Stop
Low Pressure
Start Seq
Start Button
service@paramina.gr
- website:
internal pressure
delivery pressure
Motor
Stop
High
Pressure
Start Seq
Start Button
www.paramina-compressors.com
Trip Condition
or Stop
Sequence
Time