FILTER HEAD & FILTER HOUSING SHOULD BE ADJOINED ON TOP WHEN REINSTALLING.
Replacement of coalescing cartridge & active carbon – molecular sieve cartridge
1. Unscrew the filter head counter clockwise.
2. Remove the filter head and the spring.
3. Place the special handle on top of the A.C.-M.S cartridges.
4. Remove the A.C.-M.S. cartridges by pulling upwards with the special handle. Before throwing away the
used cartridges, do not forget to remove the cartridge connector.
5. Unscrew and remove the filter housing from filter's base.
6. Unscrew and remove the coalescing connector & cover.
7. Remove the coalescing cartridge by pulling upwards.
8. Lay a small amount of silicone grease on the o-rings of filter's base. If there is a trace of damage on the o-
rings, replace.
9. Install the new coalescing cartridge on filter's base by fastening it down with your hand.
10. Wrap a small amount of Teflon around the thread of the tube connector.
11. Screw the cartridge connector & cover on the tube connector (on top of the coalescing cartridge).
12. Clean the inside of the filter housing with a clean cloth.
13. Screw the filter housing back on its base.
14. Remove the new A.C.-M.S. cartridges from their protective case. Be sure that packaging is not punctured.
If it is damaged do not use it.
15. Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
16. Screw the two A.C.-M.S. cartridges together so as to create a solid body.
17. Replace the o-ring of the cartridge connector, lay a small amount of silicone grease on the new o-ring and
then screw the connector on the bottom A.C.-M.S. cartridge.
18. Place the new A.C.-M.S. cartridge in the filter housing and fasten it down by hand on the coalescing
connector (see also drawing nr. B).
19. Lay a small amount of silicone grease on the o-rings of the filter head. If there is a trace of damage on the
o-rings, replace.
20. Install the spring in between the filter head and the cartridge.