Paramina CYCLONE SILENT 24E User Manual page 46

Table of Contents

Advertisement

User Manual - Cyclone Silent -
Compressor does not
attain final pressure
Safety valves between
individual stages
releasing pressure
Compressor runs too
hot
Oil residue/Oil smell in
delivered air
* Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 &
208704200.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
1-2018 edition
8.Wrong cable diameter or long cable
9.Interstage safety valves leaking
1.Condensate drain Valve and / or fittings
leaking
2.Premature opening of final safety valve
3. Excessive piston clearance
4. Final Safety valve's safety lock opens
prematurely
5.Interstage safety valves leaking
6.Final stage piston rings worn
st
1.If the 1
stage safety valve is released,
nd
the 2
stage valves do not close properly.
nd
2.If the 2
stage safety is released, the 3
stage valves do not close properly.
th
3.Stacked 4
stage piston
4. Blocked Sintered Filter of 3
nd
separator (when 2
stage safety valve
opens)*
5. Blocked Sintered Filter of 4
rd
stage separator (when 3
valve opens)*
1.Insufficient supply of fresh cooling air
2.Intake or outlet valves are not closing
properly
3.Wrong direction of rotation
4.Low oil level
1.Improper maintenance of final filter
2.Wrong type of oil
3.Activated carbon saturated
st
nd
rd
4.1
, 2
, or 3
stage piston rings worn
5. Worn Cylinders
service@paramina.gr
8.Check - Replace
9.Check - Replace
1.Tighten and reseal
2.Clean final safety valve and readjust
3. Replace and regulate again
4. Check the intermediate pressures,
regulate or replace valves
5.Check - Replace
9.Check - Replace
1.Check – replace valves
rd
2.Check – replace valves
3.Replace
rd
stage
4.Clean or Replace
th
– final
stage safety
5.Clean or Replace
1.Check location. Check inlet air
suction. Max. ambient temperature
under 45 ºC
2.Check and clean valves, Replace if
necessary
3.See arrow on the compressor and
remedy accordingly
4.Check oil level
1.Service filter - Renew BA cartridge
2.Use right type of oil
3.Renew BA cartridge
4. Check - Replace
5. Check - Replace
- website:
www.paramina-compressors.com
46

Hide quick links:

Advertisement

Table of Contents
loading