User Manual - Typhoon Open –

Condensate drainage

Manual drain system
Each time you stop the compressor open the manual drain valves (1, 2) so as to remove condensate. During every
start of the compressor, open only BA filter's drain valve (1). Then during the regular operation of the compressor
nd
open both 2
(1) and BA filter (2) drains every 15 (2
*If the compressor is equipped with the option of final stage separator, open its manual drain (3) for drainage
instead of BA filter drain (1). In this case, BA filter's manual drain will be used only for checking BA filter's
air/condensate quality once per day.
A. Option Two timers – Old version + T.OP.15ED & 18ED:
B. Standard equipment in all electric versions.
C. Optional equipment in petrol and diesel versions.
The system consists of two timer controlled condensate drains, one after the 2
the BA filter or the final stage separator. The drains are controlled electronically and open automatically.
Max. operating pressure: 2
In case of emergency (damaged auto drain system), the user may use the two manual drains. During routine
operation open both drain valves every 15 (2
1
The user can adjust the interval time (2) from 0,15 -
15 sec (proposed time 1,5sec), and the discharge
time (1) from 0,15 - 15 min (proposed time 15
min),
nd
Note for 2
Stage drain only: The numerous at
internal time (2) are at a percentage of 15sec. So at
internal time (2) 1,5 sec = 10(%). Respectively the
numerous at discharge time (1) are at a percentage
of 15min, so 15min = 100(%)
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
01/2018 edition
nd
2
nd
stage drain valve: 80 bar, 3
nd
stage) & 20 (3
2nd Stage
2
service@paramina.gr
rd
stage) & 20 (3
– final stage ) minutes.
3
rd
stage drain valve: 250 or 350 bar
rd
– final stage) minutes.
3rd Stage
1
The user can adjust the interval time (2) from 0,5 -
45 min (proposed time 20min), and the discharge
time (1) from 0,5 - 10 sec
sec).
- website:
www.paramina-compressors.com
1
nd
,
one after the final stage on
and
2
(proposed time 2-3
.
16