5.3.4. P00 - User Menu 
The User menu shows normal operational values and information displays. This is the default display menu; no
access code is required.
item
description
1
Compressor status
2
Cabinet temp
3**
3rd stage press
4
Delivery press
5
Hours Run
6
Oil service hrs
7
BA filter service hrs
* All values shown in display column are ONLY examples.
** Only shown if enabled
Status Information Item:
The page 0 'Status Information Item' provides a basic overview of status using symbols. Press the 'C' button at any
time while in normal operation, menu P00, to view this menu item.
The mode of operation is displayed as the status information item identifier:
S>
Semi Automatic Mode (normal operational mode)
F>
Fully Automatic Mode (normal operational mode)
TS
Safety valve test (test mode)
TL
Leakage test (test mode)
5.3.5. P01 - Operation Menu 
Contains general operation parameters that may be modified by the User from time to time.
item
description
1
Compressor mode
2
unload pressure**
3
load pressure**
4
cutout pressure
5
Drain open time before start
6
Drain open time after start
7
Drain exhaust time
8
Drain 1 open time
9
Drain 1 interval time
10
Drain 2 open time
11
Drain 2 interval time
12
Drain 3 open time
13
Drain 3 interval time
14
pressure
units
15
temperature
units
* All values shown in display column are ONLY examples.
** Minimum differential between load and unload set points is 5 bar for a 225/350 bar machine, and 0.5 bar for a
35 bar machine.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
1-2018 edition
units
step
min
---
no_edit
---
°C/°F
no_edit
---
bar/psi
no_edit
---
bar/psi
no_edit
---
H
no_edit
---
H
no_edit
---
H
no_edit
---
units
step
0/1
1
bar/psi
1
0.1
bar/psi
1
0.1
bar/psi
1
0.1
s
1
s
1
s
1
s
1
m
1
s
1
m
1
s
1
m
1
0=bar
1
1=psi
2=kPA
0
0=
C
1
0
1=
F
service@paramina.gr
max
---
S>
Semi Automatic mode
F>
Fully Automatic mode
TS
Safety valve test
TL
Leakage test
TO
Output test
0
---
T2
100
C
---
P2
50 bar
---
Pd
270 bar
---
H1
0 hrs
---
H2
500 hrs
---
H3
500 hrs
min
max
0
1
0 => M> S (Semi)
1 => M> F (Full)
55.0
390.0
Pu
5.5
59.0
50
385.0
PL
5.0
58.5
55.0
390.0
Pc
5.0
59.0
1
10
db
1
10
dA
1
20
dE
1
5
d1
1
20
d1
1
5
d2
1
20
d2
1
5
d3
1
20
d3
0
2
P>
0
1
T>
- website:
www.paramina-compressors.com
display*
display*
225 bar
215 bar
235 bar
8 s
6 s
10 s
3 s
4 m
3 s
4 m
3 s
4 m
0
0
22