REFRIGERANT

The correct type of refrigerant will be
stamped on each merchandiser's serial plate.
The case refrigeration piping is leak tested,
factory sealed and pressurized. Before
making refrigeration hookups, depress the
universal line valve to ensure that coils have
maintained pressure during shipment.
WARNING
!
Refrigeration lines are under pressure and
should be depressurized before attempting to
make any connections.

REFRIGERANT PIPING

Connection Location

The refrigerant line connections are at the right-
hand end of case (end opposite the main serial
plate) beneath the display pans. A sticker marks
the location of the connection. The installer must
saw a hole to exit the case.
A refrigeration shroud ships with each case. Be-
fore making connections, place the refrigeration
shroud over refrigeration piping so that when the
shroud is rotated into place, it will be in the
upright position. The Figure 2-1 shows the correct
orientation.
Be careful not to burn, scorch or over-heat the
shroud when making connections.
Once connections have been made, apply silicone
sealant to the bottom of the shroud as shown in
Figure 2-2.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

REFRIGERATION / ELECTRICAL

Figure 2-1
Place shroud over
refrigerant piping.
Refrigeration
Shroud
Figure 2-2
Complete piping
connections.
Apply Sealant
Low Temperature
2-1