Attach The Ebs Drop Wires - ADC PRL-783 Manual

Table of Contents

Advertisement

SCP-PRL783-012-03H

Attach the EBS Drop Wires

If this unit has been pole mounted, ADC recommends that the subscriber drop wires be connected directly to the
appropriate gas-tube protection binding posts.
1
Thread the subscriber wire pairs through the hole made earlier in the right-hand rubber grommet (see
Figure
8).
2
Lift the Line Module door, and insert the EBS wire pair through the cutout on the right side of the Line
Module door. The HDSL Tip and Ring wires, which you installed in the previous section, are not shown in
this graphic.
3
Connect the Tip wire to the Line Module green terminal gas-tube protection binding post, connect the Ring
conductor to the red terminal gas-tube protection binding post, then close the Line Module door
4
Repeat steps 1, and 2 for each EBS line to be installed, then close the Line Module door.
EBS pairs are Tip and Ring sensitive. If these lines are switched, the unit will not operate correctly.
PG-Plus PRL-783
Figure 8. Inserting the EBS Wires
RJ-11 jack
Tip (green)
Figure 9. Attaching the EBS Wire Pair
January 6, 2003
Line Module
EBS wire pair
Ring (red)
Installation and Test