[A] Cleaning Procedure - Hoshizaki KM-2400SRH3 Instruction Manual

Stackable crescent cuber
Hide thumbs Also See for KM-2400SRH3:
Table of Contents

Advertisement

[a] CLEANING PROCEDURE

[a] CLEANING PROCEDURE
[a] CLEANING PROCEDURE
[a] CLEANING PROCEDURE
[a] CLEANING PROCEDURE
1) Dilute approximately 38 fl. oz. of recommended cleaner Hoshizaki "Scale Away" or "LIME-A-
WAY," (Economics Laboratory, Inc.) with 7 gal. of water.
2) Remove all ice from the Evaporator and the Storage Bin.
Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after 3
minutes. The defrost cycle starts and the cubes will be removed from the Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel, and then remove the Insulation Panel by first removing the
Thumbscrew, lifting up the panel slightly and pulling it toward you.
5) Remove the Cap located on the front bottom part of the Ice Dropping Hole. Drain the Water
Tank. See Fig. 13.
6) Replace the Cap in its correct position.
7) Pour the cleaning solution into the Water Tank.
8) Fully open the Cleaning Valve on the left side wall of the machine compartment.
9) Move the Control Switch, on the Control Box, to the "WASH" position
10) Replace the Insulation Panel and the Front Panel in their correct positions.
11) Turn on the power supply, and start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the Front Panel and the Insulation Panel.
14) Remove the Cap located on the front bottom part of the Ice Dropping Hole. Drain the Water
Tank. Replace the Cap and the Insulation Panel in their correct positions.
15) Move the Control Switch to the "ICE" position.
16) Close the Cleaning Valve.
17) Replace the Front Panel in its correct position.
18) Turn on the power supply to fill the Water Tank with water.
19) Turn off the power supply after 3 minutes.
24