Troubleshooting

Malfunction
Sensor light fixture
without power
Sensor light fixture
does not switch on
Sensor light fixture
does not switch off
Sensor light fixture
keeps switching on and off
Sensor light fixture switches
on when it should not
Range of sensor light fixture
changes

Declaration of conformity

This product is in confor-
mity with standards of low
voltage in accordance with
12
18.02.2003
9:06 Uhr
Cause
y Fuse has blown; not
switched on; break in
wiring
y Short-circuit
y Lighting controller set to
nighttime mode during
daytime operation
y Bulb burned out
y Power switch off
y Fuse blown
y Detection zone not
properly targeted
y Internal circuit-breaker
has opened
y Continuing movement in
monitoring zone
y Set to continuous opera-
tion by indoor multi-
circuit switch
y Animals moving in detec-
tion zone
y Wind is moving trees or
bushes in detection zone
y Cars in the street are
being detected
y Sunlight is striking the
lens
y Reflection from light-
colored walls or pave-
ments
y Sudden temperature
changes due to weather
(wind, rain, snow) or
exhaust air from fans or
open windows
y Differing ambient tempe-
ratures
the regulations 73/23/EEC,
89/336/EEC.
Seite 12
Remedy
y Replace fuse; switch on
power switch; check wir-
ing with voltage tester
y Check connections
y Adjust setting
y Replace light bulb
y Switch on
y Replace fuse, check
connection if necessary
y Recalibrate
y Switch SensorLamp off
and then on again
y Check detection zone
and recalibrate if
necessary
y Switch multi-circuit
switch to automatic
y Tilt sensor higher;
change detection zone
y Change detection zone
y Change detection zone,
tilt sensor down
y Install sensor in shel-
tered spot, or change
detection zone
y Re-adjust lighting con-
troller
y Change detection zone
or install at different spot
y When it is cold, shorten
range by tilting sensor
down
y When it is hot, tilt sensor
up