Removal And Replacement Of Electrical System - Hoshizaki DCM-500BAF Service Manual

Cubelet ice dispenser
Hide thumbs Also See for DCM-500BAF:
Table of Contents

Advertisement

5) Disconnect the Flush Water Valve from the tube connected to the plastic tee leading
to the drain hose.
6) Disconnect the Terminals from the Flush Water Valve.
7) Remove the Flush Water Valve from the Frame or Bracket.
8) Connect the new Flush Water Valve back onto the Frame or Bracket.
9) Connect the tube from the plastic tee to the new Flush Water Valve.
10) Connect the Hose to the Flush Water Valve and secure it with the Clamp.
11) Pour water into the Reservoir, and check for water leaks on the Flush Water Valve.
12) Open the Water Supply Line Shut-off Valve.
13) Turn on the power supply.

12. REMOVAL AND REPLACEMENT OF ELECTRICAL SYSTEM

[a] BIN CONTROL (PROXIMITY SWITCH)
1) Turn off the power supply.
2) Remove the Front Panel and Top Panel.
Note: The Proximity Switch is located on the outside of the Bin Top Panel.
3) Cut the leads at the wire connectors.
4) Remove the Switch Cover and the Proximity Switch.
5) Install the new Proximity Switch.
6) Replace the Switch Cover in its correct position.
7) Connect the leads of the Proximity Switch.
8) Turn on the power supply.
9) To check the Bin Control operation, move the paddle located on the inside of the Bin
Top Panel. The Compressor should stop 90 sec. later, and the Gear Motor 150 sec.
later.
10) Replace the panels in their correct position.
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcm-750bafDcm-500bwfDcm-750bwf