8. REMOVAL AND REPLACEMENT OF FAN MOTOR

1) Turn off the power supply and remove the panels.
2) Remove the wire connectors from the Fan Motor leads.
3) Remove the Fan Motor Bracket and Fan Motor.
4) Install the new Fan Motor.
6) Replace the Fan Motor Bracket and the wire connectors.
7) Replace the panels in their correct position, and turn on the power supply.
9. REMOVAL AND REPLACEMENT OF CONTROL /DISPENSING WATER
VALVE
1) Turn off the power supply, remove the panels and close the Water Supply Line Shut-off
Valve.
2) Disconnect the Terminals from the Control/Dispensing Water Valve.
3) Loosen the Fitting Nut on the Control/Dispensing Water Valve Inlets, and remove the
Control/Dispensing Water Valve. Do not lose the Packings inside the Fitting Nut.
4) Remove the Water Supply Hose or Water Pipe from the Control/Dispensing Water
Valve.
5) Install the new Control/Dispensing Water Valve.
6) Assemble the removed parts in the reverse order of which they were removed.
7) Open the Water Supply Line Shut-off Valve.
8) Check for water leaks.
9) Replace the panels in their correct position, and turn on the power supply.