All models:
18 Check each battery pack and verify that
the batteries are wired correctly.
19 Inspect the battery charger plug and pigtail
for damage or excessive insulation wear.
Replace as required.
20 Connect the battery charger to a properly
grounded 110 - 230V / 50 – 60 Hz single
phase AC power supply.
⊙ Result: The charger should operate and
begin charging the batteries.
¤ Result: If, simultaneously, the charger alarm
sounds and the LEDs blink, correct the
charger connections at the fuse and battery.
The charger will then operate correctly and
begin charging the batteries.
Note: For best results, use an extension of
adequate size with a length no longer than
15m.
The following must be measured and recorded
once the battery has been fully charged, after
a waiting time of at least 12 hours:
- Total voltage
- Individual voltage of the block battery
If significant changes to previous
measurements or differences between the
block batteries are identified, then customer
service must be contacted for further testing or
repairs.
Note: If you have any further questions
regarding the battery charger operation,
please contact the DINGLI Service
Department.
B-2
Inspect the Electrical Wiring
DINGLI requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Maintaining electrical wiring in good condition
is essential to safe operation and good
machine performance. Failure to find and
replace burnt, chafed, corroded or pinched
wires could result in unsafe operating
conditions and may cause component
damage.
Electrocution / burn hazard.
Contact with electrically charged circuits could
result in death or serious injury. Remove all
rings, watches and other jewelry.
1
Inspect the underside of the chassis for
damaged or missing ground strap(s).
2
Inspect the following areas for burnt,
chafed, corroded and loose wires:
• Ground control panel
• Hydraulic power unit module tray
• Battery pack module tray
• Platform controls
3
Turn the key switch to ground control. Turn
the ground red Emergency Stop button
clockwise to the on position. Pull out the
platform red Emergency Stop button to the
on position.
4
Raise the platform until the distance of the
two sets of scissor at least 0.5m.
5
Lift the safety arm, move it to the center of
the scissor arm and rotate up to a vertical
position.