E-Tech S06-HAE Operators Manual With Maintenance Information page 56

Table of Contents

Advertisement

extension deck by foot.
2
Push the platform extension guardrail to
extend the platform to the desired position.
Do not stand on the platform extension
while trying to extend it.
Anti-collision protection Safety
function introduction (if
equipped)
When the anti-collision protection function is
activated, there are three levels of prompts
(Danger Warnings).
1
When the Ultrasonic sensor (platform
control panel) is 4 meters away from the
obstacle zone, the machine will alarm (50
beeps per minute).
2
When the Ultrasonic sensor (platform
control panel) is 2 meters away from the
obstacle zone, the machine will alarm (110
beeps per minute).
Note: The above two levels do not limit the lift
function.
3
When the Ultrasonic sensor (platform
control panel) is 1.5 meters away from the
obstacle zone, the lift function is disabled,
and the alarm will be constant.
After the lift function is disabled, release the
joystick back to neutral position (center) and
operate the joystick to lift again within 5
seconds (within the time of the alarm
sounding), with in this period the machine will
be enabled to lift again; at this point if not
operated to lift again after 5 seconds (the
alarm is relieved), the machine cannot be lifted
and alarm sounds again.
Note: After the anti-collision protection function
is triggered, the machine can only be operated
by lowering the height of the platform or driving
to an open position. Do not remove the
OPERATOR'S MANUAL with Maintenance Information
Operating Instructions
ultrasonic sensor and the wiring harness
connected to the platform control to relieve the
limit.
Sensor Characteristic Response Curve
(Default curve: wide sound lobe)