Adjustment procedures
1.
Remove the top cover.
Loosen screw ❶ .
2.
Turn the eccentric cam ❷ . The direction of turning the eccen-
3.
tric cam and the relation between the eccentric cam and the
needle thread loop is shown in the following table.
•
Size of needle thread loop
A : Move forward
Loop becomes smaller. Loop becomes larger.
After the adjustment, fully tighten screw ❶ .
4.
* With the factory-adjusted value at the time of shipment, the
marker lines C are aligned.
B : Move backward
– 9 –
Results of Improper adjustment