Chapter 9 Maintenance And Inspection; Basic Inspection - Delta Electronics ASDA-A Series User Manual

Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

ASDA-A User Manual

Chapter 9 Maintenance and Inspection

Delta AC servo drives are based on solid state electronics technology. Preventive maintenance is required to
operate this AC servo drives in its optimal condition, and to ensure a long life. It is recommended to perform
a periodic maintenance and inspection of the AC servo drive by a qualified technician. Before any
maintenance and inspection, always turn off the AC input power to the unit.
Be sure to disconnect AC power and ensure that the internal capacitors have fully
WARNING
discharged before performing the maintenance and inspection!
9-1

Basic Inspection

After power is in connected to the AC servo drive, the charge LED will be lit which indicates that the AC
servo drive is ready.
Inspection Item
General Inspection
Inspection before
operation
(Control power is not
applied)
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1. Periodically inspect the screws of the servo drive, motor shaft, terminal block
and the connection to mechanical system. Tighten screws as necessary as
they may loosen due to vibration and varying temperatures.
2. Ensure that oil, water, metallic particles or any foreign objects do not fall
inside the servo drive, motor, control panel or ventilation slots and holes. As
there will cause damage.
3. Ensure the correct installation and the control panel. It should be free from
airborne dust, harmful gases or liquids.
4. Ensure that all wiring instructions and recommendations are followed,
otherwise damage to the drive and or motor may result.
1. Ensure that all wiring terminals are correctly insulated.
2. Ensure that all wiring is correct or damage and or malfunction may result.
3. Visually check to ensure that there are not any unused screws, metal strips,
or any conductive or inflammable materials inside the drive.
4. To avoid an electric shock, be sure to connect the ground terminal of servo
drive to the ground terminal of control panel. Before making any connection,
wait 10 minutes for capacitors to discharge after the power is disconnected,
alternatively, use an appropriate discharge device to discharge.
5. Make sure control switch is OFF.
6. Never put inflammable objects on servo drive or close to the external
regenerative resistor.
7. If the electromagnetic brake is being used, ensure that it is correctly wired.
8. If required, use an appropriate electrical filter to eliminate noise to the servo
drive.
9. Ensure that the external applied voltage to the drive is correct and matched to
the controller.
Chapter 9 Maintenance and Inspection
Inspection Content
9-1
4th Edition 2005/11/30, HE03

Advertisement

Table of Contents
loading

Table of Contents