Detailed Parameter Listings - Delta Electronics ASDA-A Series User Manual

Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Chapter 7 Parameters
7-3

Detailed Parameter Listings

Group 0: P0-xx Monitor Parameters
P0 - 00
VER
Software Version
Default: Factory setting
P0 - 01
ALE
Drive Fault Code
Range: 00~22
Setting:
01: Overcurrent
02: Overvoltage
03: Undervoltage
04: Motor overheated
05: Regeneration error
06: Overload
07: Overspeed
08: Abnormal pulse control command
09: Excessive deviation
10: Watch dog fault
11: Position detector fault
12: Adjustment error
13: Emergency stop
14: Reverse limit error
15: Forward limit error
16: IGBT temperature error
17: Memory error
18: DSP communication error
19: Serial communication error
20: Serial communication time out
21: DSP to MCU command write-in error
22: Input power phase loss
P0 - 02
STS
Drive Status
Default: 00
Range: 00~16
Setting:
00: Motor feedback pulse number (absolute value)
01: Motor feedback rotation number (absolute value)
02: Pulse count of pulse command
4th Edition 2005/11/30, HE03
7-20
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
ASDA-A User Manual
Communication Addr.: 0000H
Applicable Control Mode: P/S/T
Communication Addr.: 0001H
Applicable Control Mode: P/S/T
Communication Addr.: 0002H
Applicable Control Mode: P/S/T