Convenience Operation - Panasonic CS-A18CKPG Service Manual

Hide thumbs Also See for CS-A18CKPG:
Table of Contents

Advertisement

I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 to select:-
AUTO
For COOL/DRY operation.
AUTO
Swing up/down automatically.
For HEAT operation
AUTO
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.
AUTO HEAT
COOL
DRY FAN
AUTO
AUTO
FAN
8
OFF/ON
POWERFUL
MODE
ECONOMY
SLEEP
7
AIR SWING
FAN SPEED
1
2
3
1
ON
SET
5
OFF
CANCEL
TIMER
CHECK
RESET CLOCK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
I ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
I OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
G Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
COOL, DRY –> 15 minutes in advance
HEAT, AUTO –> 30 minutes in advance
• Once the ON/OFF Timer is set, operation will
start/stop at the set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
I Setting the Horizontal Airflow Direction
• Press 6 to select:-
Indoor
Horizontal
Unit
Airflow
Direction
Remote
Control
For COOL/DRY operation.
AUTO
Swing left/right automatically.
For HEAT operation
AUTO
There is no air swing during the discharge
air temperature is low. When the temperature
rises, the horizontal airflow louvers swing
left/right automatically.
G Use this air conditioner under the following
conditions:
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
G Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

CONVENIENCE OPERATION

I Sleep Mode Operation
To obtain a comfortable room temperature while
sleeping:-
• Press 6.
6
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
3
G Sleep Mode Operation Details
4
• When the room temperature reaches the set
2
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a
priority.
Temperature
S
T
Approx.
e
e
1°F
m
t
increase.
p
t
e
i
r
n
a
g
t
u
r
e
Sleep
Operation
Approx. 4°F
button is
← 1 hour →
decrease.
pressed.
← 1 hour →
0~1 hour
AUTO
(Unit in °C)
Outdoor
Indoor
DBT
WBT
DBT
WBT
32
23
43
26
(30)
(-)
(24)
(18)
16
11
16
11
(16)
(-)
(-5)
(-6)
Approx. 1°F
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
Sleep shift
operation starts.
• Heating operation for
sleep shift operation will
start to avoid overheating.
Approx. 5°F
decrease.
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
I Economy Mode Operation
To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press 7.
* Economy mode indicator (green) on the indoor unit
will light up.
• Press once more to cancel this operation.
I Powerful Mode Operation
To obtain the set temperature quickly.
• Press 8.
* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
G Economy / Powerful Mode Operation Details
• Economy and Powerful operation cannot be
selected simultaneously.
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If sleep button or operation mode button is pressed,
economy or powerful operation will be cancelled.
Economy Mode
Temperature
Operation
1°F higher
COOL / DRY
than set temp.
1°F lower
HEAT
than set temp.
Powerful Mode
Temperature
Operation
5°F lower
COOL / DRY
than set temp.
5°F higher
HEAT
than set temp.
Airflow
volume
Super Low
Automatic
Airflow
volume
Super High
Automatic