8.4 Automatic Mode Operation
TOP PREVIOUS NEXT
1. When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for
25 seconds to sense intake air temperature and determine the 1st operation mode. If indoor
intake air temperatureis less than 16°C, Heating mode will immediate operate.
2. Operation mode will be determine again after 1 hour of operation, if the room temperature
reaches to set temperature and compressor off time is over 7 minutes 30 seconds continuously.
The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps
running) even though after 1 hour from automatic operation mode started.
Present
Judgement
Mode
Cooling 23°C
Cooling
Heating
Soft Dry 23°C
Soft Dry
Heating
Heating
Cooling
23°C
Heating
Automatic Set TemperatureRefer 3. as below.
Next Mode
Cooling
Soft Dry
O
(Judgement:
Not Applicable
23°C & Above)
O
Not Applicable
(Judgement:
23°C & Above)
O
(Judgement:
Not Applicable
Above 23°C)
Heating
O
(Judgement:
Below 23°C)
O
(Judgement:
Below 23°C)
O
(Judgement:
23°C & below)