mode.
When set a Airflow Direction Auto-Control with remote control, the vanes swings left and
●
right as shown in the diagram.
The vanes does not swing when the Indoor Fan Motor stops during operation at 22° angle.
●
When stopped with remote control, the discharge vent is reset, and stopped at the reset
●
position.
During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from
●
0° - 44° to 14° - 30° under Cooling and Soft Dry operation mode.
1. There is no swinging while indoor fan motor is stopped during Cooling and Soft Dry operation.
2. In Heating operation, when the intake air temperature reaches set temperature, the airflow direction is Auto Swing left and right. When
the intake air temperature falls to 2°C lower than set temperature,the airflow direction is stop at 22° angle.
When the manual Airflow Direction Selection Button is pressed, the automatic airflow is
●
released and the airflow direction vane move left and right in the range shown in the diagram.
Horizontal Airflow Direction Auto-Control
Horizontal Airflow Direction manual Control