Convenience Operation - Panasonic CS-A7BKP Service Manual

Table of Contents

Advertisement

CS-A7BKP CU-A7BKP5 / CS-A7BKP CU-A7BKP6 / CS-A9BKP CU-A9BKP5 / CS-A9BKP CU-A9BKP6 / CS-A12BKP CU-A12BKP5 / CS-A12BKP CU-A12BKP6
■ Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
■ Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
FAN Operation
AUTO
AUTO
36°
61°
Swing up/down
Swing up/down
Automatically
Automatically
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
0° ~ 61°.
14° ~ 36°.
Heat Pump Model
COOL / DRY Operation
HEAT Operation
AUTO
AUTO
– When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
36°
at horizontal level. As
the temperature rises,
the hot air blows at a
Swing up/down
downward direction.
Automatically
– To stop this op-eration,
press MANUAL.
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
14° ~ 36°.
0° ~ 61°.
AUTO HEAT
COOL
DRY FAN
AUTO
AUTO
FAN
8
OFF/ON
POWERFUL
MODE
ECONOMY
SLEEP
7
6
AIR SWING
AUTO
MANUAL
FAN SPEED
1
2
3
1
3
SET
ON
5
4
OFF
CANCEL
2
TIMER
CHECK
RESET CLOCK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
■ ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
■ OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
● Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
Cooling Model
Heat Pump Model
COOL,DRY, – 15 minutes
COOL,DRY, – 15 minutes
in advance
AUTO
in advance
HEAT, AUTO – 30 minutes
in advance
• Once the ON-Timer is set, operation will start at the
set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
■ Setting the Horizontal Airflow Direction
• Adjust it manually
● Use this air conditioner under the following
conditions:
Cooling Model
Unit in °C
Indoor
Outdoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature
32
23
43
Minimum Temperature
16
11
16
Heat Pump Model
Unit in °C
Indoor
Outdoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
DBT
WBT
Maximum Temperature-Cooling
32
23
43
(Maximum Temperature-Heating)
(30)
(-)
(24)
(18)
Minimum Temperature-Cooling
16
11
16
(Minimum Temperature-Heating)
(16)
(-)
(-5)
(-6)
● Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.

CONVENIENCE OPERATION

■ Sleep Mode Operation
To obtain a comfortable room temperature while
sleeping:-
• Press 6.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
● Sleep Mode Operation Details
• When the room temperature reaches the set
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a
priority.
Cooling Model
Temperature
Approx. 0.5°C
increase.
Approx.
S
T
0.5°C
e
e
increase.
m
t
• Cooling or Soft Dry
p
t
Sleep
e
Operation for sleep shift
i
Operation
r
operation will start to
Sleep shift
n
a
button is
avoid overcooling.
operation
g
t
pressed.
starts.
u
r
← 1 hour →
0~1 hour
e
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Heat Pump Model
Temperature
Approx. 0.5°C
increase.
S
T
Approx.
e
e
0.5°C
m
t
• Cooling or Soft Dry
increase.
p
t
Operation for sleep shift
e
i
operation will start to
r
n
avoid overcooling.
a
Sleep shift
g
t
operation starts.
u
• Heating operation for
r
e
sleep shift operation will
Sleep
start to avoid overheating.
Operation
Approx. 2°C
button is
← 1 hour →
decrease.
pressed.
Approx. 3°C
← 1 hour →
decrease.
0~1 hour
after approx. 8 hours of sleep shift
operation, it will stop automatically.
35
● Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
(for Heat Pump Model only)
26
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
11
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
26
When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
11
2°C below the set temperature.
(It is useful when using a heater).
■ Economy Mode Operation
To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press 7.
* Economy mode indicator (green) on the indoor unit
will light up.
• Press once more to cancel this operation.
■ Powerful Mode Operation
To obtain the set temperature quickly.
• Press 8.
* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
● Economy / Powerful Mode Operation Details
• Economy and Powerful operation cannot be
selected simultaneously.
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If sleep button or operation mode button is pressed,
economy or powerful operation will be cancelled.
• During FAN – Air circulation operation, the powerful
and economy operation are not available.
Time
(cooling model only)
Economy Mode
Temperature
Operation
0.5°C higher
COOL / DRY
than set temp.
HEAT
0.5°C lower
(for Heat Pump
than set temp.
model only)
Powerful Mode
Temperature
Operation
3°C lower
COOL / DRY
than set temp.
HEAT
3°C higher
(for Heat Pump
than set temp.
model only)
Time
Airflow
volume
Super Low
Automatic
Airflow
volume
Super High
Automatic