Panasonic CS-A18NKS Operating Instructions Manual
Panasonic CS-A18NKS Operating Instructions Manual

Panasonic CS-A18NKS Operating Instructions Manual

Indoor/outdoor unit

Advertisement

Quick Links

‫ﺩﻟﻴﻞ ﺳﺮﻳﻊ‬
‫ﺩﻟﻴﻞ ﺳﺮﻳﻊ‬
QUICK GUIDE
QUICK GUIDE

Operating Instructions

Model No.
Indoor Unit
CS-A18NKS
CS-A24NKS
ENGLISH
Before operating the unit, read these operating
instructions thoroughly and keep them for future
reference
© Panasonic Appliances Air-Conditioning Malaysia
Sdn. Bhd. 2012. Unauthorized copying and distribution
is a violation of law.

Air Conditioner

Outdoor Unit
CU-A18NKS
CU-A24NKS
F568390

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CS-A18NKS

  • Page 1: Operating Instructions

    Before operating the unit, read these operating instructions thoroughly and keep them for future reference ‫ﺩﻟﻴﻞ ﺳﺮﻳﻊ‬ ‫ﺩﻟﻴﻞ ﺳﺮﻳﻊ‬ © Panasonic Appliances Air-Conditioning Malaysia QUICK GUIDE QUICK GUIDE Sdn. Bhd. 2012. Unauthorized copying and distribution is a violation of law.
  • Page 2: Table Of Contents

    ‫ﻣﻼﺣﻈﺔ : ﺍﻟﺮﺳﻮﻣﺎﺕ ﺍﻟﺘﻮﺿﻴﺤﻴﺔ ﻓﻲ ﻫﺬﺍ ﺍﻟﻜ ﺘ ﹼ ﻴﺐ ﻫﻲ ﻻﻏﺮﺍﺽ ﺍﻟﺸﺮﺡ ﻓﻘﻂ ﻭﳝﻜﻦ ﺍﻥ ﺗﺨﺘﻠﻒ ﻋﻦ ﺍﻟﻮﺣﺪﺓ ﺍﳊﻘﻴﻘﻴﺔ. ﺇﻧﻬﺎ ﻣﻌﺮﺿﺔ ﻟﻠﺘﻐﻴﻴﺮ‬ .‫ﺑﺪﻭﻥ ﺍﺷﻌﺎﺭ ﻣﺴﺒﻖ ﻣﻦ ﺍﺟﻞ ﺍﻟﺘﺤﺴﲔ ﻓﻲ ﺍﳌﺴﺘﻘﺒﻞ‬ ENGLISH Thank you for purchasing Panasonic Air Conditioner TABLE OF CONTENTS TABLE OF CONTENTS...
  • Page 3 ‫ﺣﺎﻟﺔ ﺍﻟﺘﺸﻐﻴﻞ‬ ‫ﺣﺎﻟﺔ ﺍﻟﺘﺸﻐﻴﻞ‬ ‫ﺍﺳﺘﻌﻤﻞ ﻣﻜ ﻴ ﹼ ﻒ ﺍﻟﻬﻮﺍﺀ ﲢﺖ ﻣﺪﻯ ﺩﺭﺟﺎﺕ ﺍﳊﺮﺍﺭﺓ ﺍﻟﺘﺎﻟﻴﺔ‬ ‫ﺍﳋﺎﺭﺟﻴﺔ‬ ‫ﺍﻟﺪﺍﺧﻠﻴﺔ‬ (‫ﺩﺭﺟﺔ ﺍﳊﺮﺍﺭﺓ )ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ‬ *WBT *DBT *WBT *DBT ٣١ ٥٥ ٢٣ ٣٢ ‫ﺃﻗﺼﻰ‬ ‫ﺍﻟﺘﺒﺮﻳﺪ‬ ١١ ١٦ ١١ ١٦ ‫ﺃﺩﻧﻰ‬ ١٨ ٢٤ ٣٠ ‫ﺃﻗﺼﻰ‬ ‫: ﺩﺭﺟﺔ...
  • Page 4 ‫ﲢﺬﻳﺮﺍﺕ ﻣﻦ ﺍﺟﻞ ﺍﻟﺴﻼﻣﺔ‬ ،‫ﻣﻦ ﺃﺟﻞ ﺗﻔﺎﺩﻱ ﺣﺪﻭﺙ ﺟﺮﻭﺡ ﺷﺨﺼﻴﺔ، ﺃﻭ ﺟﺮﻭﺡ ﻷﺷﺨﺎﺹ ﺁﺧﺮﻳﻦ‬ ‫ﲢﺬﻳﺮ‬ ‫ﲢﺬﻳﺮ‬ .‫ﺃﻭ ﺗﻠﻒ ﺑﺎﳌﻤﺘﻠﻜﺎﺕ، ﻳﺮﺟﻰ ﺍﻻﻣﺘﺜﺎﻝ ﳌﺎﻳﻠﻲ ﺍﺩﻧﺎﻩ‬ ‫ﺳﻮﻑ ﻳﺴﺒﺐ ﺍﻟﺘﺸﻐﻴﻞ ﻏﻴﺮ ﺍﻟﺼﺤﻴﺢ ﺑﺴﺒﺐ ﻋﺪﻡ ﺍﺗﺒﺎﻉ‬ ‫ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﺍﳌﺬﻛﻮﺭﺓ ﺍﺩﻧﺎﻩ ﺃﺫﻯ ﺃﻭ ﺿﺮﺭ ﺟﺪﹼ ﻱ. ﻛﻤﺎ ﻫﻮ ﻣﺼ ﻨ ﹼﻒ ﻓﻲ‬ ‫ﺍﻟﻮﺣﺪﺓ...
  • Page 5 ‫ﲢﺬﻳﺮ‬ ‫ﲢﺬﻳﺮ‬ ‫ﺗﻨﺒﻴﻪ‬ ‫ﺗﻨﺒﻴﻪ‬ ‫ﻣﺰﻭﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﳋﺎﺭﺟﻴﺔ‬ ‫ﻓﻲ ﺣﺎﻟﺔ ﺣﺼﻮﻝ ﺿﺮﺭ ﻟﺴﻠﻚ ﺗﺰﻭﻳﺪ ﺍﻟﻄﺎﻗﺔ‬ ‫ﻻﺗﻐﺴﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺑﺎﳌﺎﺀ، ﺃﻭ ﺍﻟﺒﻨﺰﻳﻦ، ﺃﻭ ﺍﻟﺜﻨﺮ، ﺃﻭ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ، ﻳﺠﺐ ﺗﺒﺪﻳﻞ ﺍﻟﺴﻠﻚ ﻣﻦ ﻗﺒﻞ ﺍﻟﺼﺎﻧﻊ‬ .‫ﻣﺴﺤﻮﻕ ﺍﻟﺼﻘﻞ ﻟﺘﻔﺎﺩﻱ ﺗﻠﻒ ﺃﻭ ﺗﺂﻛﻞ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺘﺺ...
  • Page 6 ‫ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ‬ ‫ﺍﺿﻐﻂ ﺯﺭ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ‬ ١ ‫ﻟﺘﺸﻐﻴﻞ ﺃﻭ ﺍﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ‬ POWER ‫• ﺍﺛﻨﺎﺀ ﺍﺳﺘﻌﻤﺎﻝ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ، ﻳﺮﺟﻰ ﺍﻻﻧﺘﺒﺎﻩ‬ :‫ﺍﳌﺴﺎﻓﺔ ﺍﻟﻘﺼﻮﻯ‬ ‫ ﺍﳌﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺷﺎﺷﺔ ﻋﺮﺽ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ‬OFF ‫ﺍﻟﻰ ﺍﺷﺎﺭﺓ‬ ‫٨ ﺍﻣﺘﺎﺭ‬ .‫ﻋﻦ ﺑﻌﺪ ﻟﺘﻔﺎﺩﻱ ﺗﺸﻐﻴﻞ/ﺍﻳﻘﺎﻑ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﺧﺎﻃﺊ‬ ‫ﻣﺘﺤﺴﺲ...
  • Page 7 ‫• ﻳﻘﻮﻡ ﻣﺘﺤﺴﺲ ﺍﻟﻨﺸﺎﻁ ﺍﻟﺒﺸﺮﻱ ﲟﺴﺢ ﻣﻨﻄﻘﺔ ﻣﺼﺪﺭ ﺍﳊﺮﺍﺭﺓ‬ ٦ ‫ﻣﻦ ﺃﺟﻞ ﺗﻨﻘﻴﺔ ﺍﻟﻬﻮﺍﺀ‬ NANOE-G .‫ﻭﺍﳊﺮﻛﺔ ﻓﻲ ﺍﻟﻐﺮﻓﺔ‬ ‫• ﺗﺰﻳﻞ / ﺗﻔﻘﺪ ﻓﻌﺎﻟﻴﺔ ﺍﳉﺴﻴﻤﺎﺕ ﺍﻟﺪﻗﻴﻘﺔ ﺍﳌﺆﺫﻳﺔ ﻣﺜﻞ‬ ‫ﺣﺮﻛﺔ ﻭﻣﺼﺪﺭ ﺍﳊﺮﺍﺭﺓ‬ ‫ﻣﺆﺷﺮ ﺍﻟﻨﺸﺎﻁ ﺍﻟﺒﺸﺮﻱ‬ .‫ﺍﻟﻔﻴﺮﻭﺳﺎﺕ، ﺍﻟﺒﻜﺘﺮﻳﺎ،...ﺍﻟﺦ‬ ‫ﻋﻨﺪ ﺍﳌﻨﻄﻘﺔ ﺍﻟﻴﺴﺮﻯ ﻣﻦ ﺍﻟﻐﺮﻓﺔ‬ ‫•...
  • Page 8 ‫ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ‬ ‫ﺍﺿﻐﻂ ﻭﺍﺣﺘﻔﻆ ﺑﻪ ﻣﻀﻐﻮﻃ ﺎ ﹰ ﳌﺪﺓ ﺗﺰﻳﺪ ﻋﻦ ٥ ﺛﻮﺍﻧﻲ‬ ‫ﻟﻀﺒﻂ ﺍﳌﺆﻗﺖ‬ ‫ﻟﻀﺒﻂ ﺍﳌﺆﻗﺖ‬ ١٠ ‫ﻣﻦ ﺍﺟﻞ ﺍﺧﻔﺎﺕ ﺳﻄﻮﻉ ﻣﺆﺷﺮ ﺍﻟﻮﺣﺪﺓ ﺃﻭ ﻻﺳﺘﻌﺎﺩﺓ‬ .‫ﺍﻟﺴﻄﻮﻉ‬ • ‫ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﺍﻟﻮﻗﺖ ﺍﳌﻀﺒﻮﻁ‬OFF ‫ ﺃﻭ ﺍﻳﻘﺎﻑ‬ON ‫ﻟﺘﺸﻐﻴﻞ‬ .‫ﻣﺴﺒﻘ ﺎ ﹰ‬ ‫ﺍﺿﻐﻂ...
  • Page 9 ‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ .‫• ﺍﻓﺼﻞ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻗﺒﻞ ﺍﻟﺘﻨﻈﻴﻒ‬ .‫• ﻻﺗﻠﻤﺲ ﺯﻋﻨﻔﺔ ﺍﻻﳌﻨﻴﻮﻡ، ﻷﻥ ﺍﳉﺰﺀ ﺍﳊﺎﺩ ﻗﺪ ﻳﺴﺒﺐ ﺟﺮﻭﺡ‬ ‫ﺗﻨﺒﻴﻪ‬ ‫ﺗﻠﻤﻴﺤﺔ ﻣﻔﻴﺪﺓ‬ ‫ﺗﻠﻤﻴﺤﺔ ﻣﻔﻴﺪﺓ‬ ‫ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﻨﻈﻴﻒ‬ ‫ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﻨﻈﻴﻒ‬ ‫• ﻟﻀﻤﺎﻥ ﺃﻓﻀﻞ ﺍﺩﺍﺀ ﻟﻠﻮﺣﺪﺓ، ﻳﺠﺐ ﺃﻥ ﺗﻨﻔﺬ ﺧﺪﻣﺎﺕ ﺍﻟﺘﻨﻈﻴﻒ‬ .‫• ﻻ ﺗﺴﺘﻌﻤﻞ ﺍﻟﺒﻨﺰﻳﻦ ﺍﻭ ﺍﻟﺜﻨﺮ ﺍﻭ ﻣﺴﺎﺣﻴﻖ ﺍﳉﻠﻲ‬ .‫ﻋﻠﻰ...
  • Page 10 ‫ﺍﻟﺒﺤﺚ ﻋﻦ ﺍﻻﻋﻄﺎﻝ ﻭﺍﻻﺻﻼﺡ‬ .‫ﻻﺗﺸﻴﺮ ﺍﻷﻋﺮﺍﺽ ﺍﻟﺘﺎﻟﻴﺔ ﺍﻟﻰ ﺣﺪﻭﺙ ﻗﺼﻮﺭ ﻓﻲ ﺍﻻﺩﺍﺀ‬ .‫ﻻﺗﺸﻴﺮ ﺍﻷﻋﺮﺍﺽ ﺍﻟﺘﺎﻟﻴﺔ ﺍﻟﻰ ﺣﺪﻭﺙ ﻗﺼﻮﺭ ﻓﻲ ﺍﻻﺩﺍﺀ‬ ‫ﺍﻟﺴﺒﺐ‬ ‫ﺍﻟﺴﺒﺐ‬ ‫ﺍﻷﻋﺮﺍﺽ‬ ‫ﺍﻷﻋﺮﺍﺽ‬ ◄ .‫• ﺗﺄﺛﻴﺮ ﺍﻟﺘﻜﺎﺛﻒ ﺑﺴﺒﺐ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺒﺮﻳﺪ‬ .‫ﻳﺨﺮﺝ ﺿﺒﺎﺏ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬ ◄ .‫• ﺗﺪﻓﻖ ﻣﺎﺩﺓ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺩﺍﺧﻞ ﺍﻟﻮﺣﺪﺓ‬ .‫ﺻﻮﺕ...
  • Page 11 ‫ﺍﳌﻌﻠﻮﻣﺎﺕ‬ ‫ﻟﻠﻔﺤﺺ ﺍﳌﻮﺳﻤﻲ ﺑﻌﺪ ﻓﺘﺮﺓ ﻃﻮﻳﻠﺔ ﻣﻦ ﻋﺪﻡ ﺍﻻﺳﺘﺨﺪﺍﻡ‬ ‫ﺍﻻﻋﻄﺎﻝ ﺍﻟﺘﻲ ﻻﳝﻜﻦ ﺍﺻﻼﺣﻬﺎ ﻣﻦ ﻗﺒﻠﻚ‬ .‫• ﺍﻓﺤﺺ ﺑﻄﺎﺭﻳﺎﺕ ﻭﺣﺪﺓ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑﻌﺪ‬ ‫ﺍﻃﻔﺊ ﻣﺼﺪﺭ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻭﺍﻧﺰﻉ ﺍﻟﻘﺎﺑﺲ ﻳﺮﺟﻰ‬ .‫• ﻻﺗﻮﺟﺪ ﻋﻮﺍﺋﻖ ﺃﻣﺎﻡ ﻓﺘﺤﺎﺕ ﻣﺪﺧﻞ ﻭﻣﺨﺮﺝ ﺍﻟﻬﻮﺍﺀ‬ :‫ﺍﺳﺘﺸﺎﺭﺓ ﺍﻟﻮﻛﻴﻞ ﺍﳌﻌﺘﻤﺪ ﻓﻲ ﺍﻟﻈﺮﻭﻑ ﺍﻟﺘﺎﻟﻴﺔ‬ ‫•...
  • Page 12: Safety Precautions

    SAFETY PRECAUTIONS To prevent personal injury, injury to others, or property damage, please comply with the following. WARNING WARNING Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below: INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons (including children) with reduced...
  • Page 13 WARNING WARNING CAUTION CAUTION POWER SUPPLY INDOOR UNIT AND OUTDOOR UNIT If the supply cord is damage, it must be replaced Do not wash the indoor unit with water, benzene, by the manufacturer, its service agent or similarly thinner or scouring powder to avoid damage or qualified persons in order to avoid a hazard.
  • Page 14: Remote Control

    REMOTE CONTROL Press the remote control’s button TO TURN ON OR OFF THE UNIT POWER Maximum • Please be aware of the OFF indication on the remote distance: 8m control display to prevent the unit from starting/stopping improperly. Human activity TO SET TEMPERATURE sensor and indicator...
  • Page 15 • The human activity sensor will also scan for area of heat TO PURIFY THE AIR NANOE-G source and movement in a room. • Removes/deactivates harmful micro-organisms such as Human activity indicator Heat source & movement viruses, bacteria, etc. At left area of the room •...
  • Page 16: Remote Control

    REMOTE CONTROL Press and hold for 5 seconds to dim or restore the TO SET THE TIMER TO SET THE TIMER unit’s indicator brightness. • To turn ON or OFF the unit at a preset time. Press and hold for approximately 10 seconds to show temperature setting in °C or °F.
  • Page 17: Indoor Unit

    INDOOR UNIT • Switch off the power supply and unplug before cleaning. • Do not touch the aluminium fin, sharp parts may cause injury. CAUTION CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS HINT HINT • Do not use benzene, thinner or scouring powder. •...
  • Page 18: Troubleshooting

    TROUBLESHOOTING The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction. SYMPTOM SYMPTOM CAUSE CAUSE Mist emerges from indoor unit. ► • Condensation effect due to cooling process. Water flowing sound during operation. ► • Refrigerant flow inside the unit. The room has a peculiar odor.
  • Page 19: Information

    INFORMATION FOR SEASONAL INSPECTION AFTER EXTENDED NON SERVICEABLE CRITERIAS NON-USE TURN OFF POWER SUPPLY AND UNPLUG then • Checking of remote control batteries. please consult authorized dealer under the following • No obstruction at air inlet and air outlet vents. conditions: •...
  • Page 20: Remote Control Preparation

    COMFORT MODE NANOE-G OFF/ON OFF/ON TEMP POWERFUL/ .‫ﺑﺪﺀ/ﺍﻳﻘﺎﻑ ﺍﻟﺘﺸﻐﻴﻞ‬ AIR SWING QUIET FAN SPEED Start/stop the operation. TIMER CANCEL TEMP TEMP CLOCK RESET .‫ﺍﺧﺘﻴﺎﺭ ﺩﺭﺟﺔ ﺍﳊﺮﺍﺭﺓ ﺍﳌﺮﻏﻮﺑﺔ‬ Select the desired temperature. Panasonic Corporation Website: http://panasonic.net/ F568390 Printed in Malaysia FS1011-0...

This manual is also suitable for:

Cu-a18nksCu-a24nksCs-a24nks

Table of Contents