CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
7.4.
Automatic Mode Operation
Standard for determining operation mode
First Determination:
Second Determination:
One hour after the above determination, the unit will operate according to the table below.
1. Indoor fan operates at super low speed for 20 seconds.
2. After judging indoor air temperature, the operation is determined and operation continued at the mode determined.
3. If indoor temperature is less than 16°C, heating operation will immediately operate.
4. After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation induces cooling
mode operation.
5. If automatic mode operation is started while the unit is operating, operation will continue.
If current operation is in cooling mode (including the cooling mode operation when is a part of Soft Dry mode operation) it will
be maintained, and if current operation is not cooling mode, the appropriate operation mode is determined for 20 seconds at
super slow fan speed.
Then the selected mode will continue.
6. Room temperature adjustment
22