Dehumidification mode
In this mode, the unit dehumidifies the room.
Selecting this mode is useful during mid-seasons,
i.e. on rainy days when the temperature is
pleasant, but the humidity excessive. The unit
runs on low fan speed regardless of settings and
room temperature. It is normal for the unit to
have an intermittent operation.
Fan mode
In this mode, neither heating, cooling nor
dehumidification is done. It is possible to select
fan speed.
Heating mode
In this mode, the unit heats the room. Set
the desired temperature between 16 and
31°C by using the up/down buttons. If the
set temperature is higher than the room
temperature, the compressor starts after max.
three minutes for heating.
In this mode, automatic defrosting is made when
necessary and heating is deactived during the
process.
Comfort mode Night
Comfort mode Night can be selected when the
unit is in cooling or heating mode, to optimse
sound level, energy savings and comfort during
the night. The unit runs with the lowest fan
speed.
• In cooling mode: the set temperature
increases by 1°C after one hour and by a
further 1°C after two hours. After this, the
set temperature does not change again and
after a further six hours the unit switches to
standby mode.
• In heating mode: the set temperature
decreases by 1°C after one hour and by a
further 1°C after two hours. After this, the
set temperature does not change again and
after a further six hours the unit switches to
standby mode.
This function is not available in dehumidifying
mode, fan mode and comfort mode, and can
be cancelled at any time by pressing the button
again. If the timer function is activated at the
same time, the unit switches off when the set
time ends.
Brightness
The display brightness sensor can be disabled
(leaving the maximum brightness at all times) by
pressing the night button for 10 seconds. "ds"
(disabled) or "En" (enabled) will appear on the
display.
Air deflector
This button sets the position of the air deflector:
• continuous oscillation - the symbol is shown
on the display
• blocked position.
NOTE!: The mobile air director must never be
moved manually. In cooling and dehumidification
mode, it resets every 30 minutes to prevent the
formation of condensation.
Soloclim vertical
Setting power
The unit has five power settings - Minimum,
Medium, Maximum, Dual Power and Automatic -
selected by pressing this key sequentially. Higher
power gives better performance but a higher
sound level.
• The Dual Power function is available in
• In Automatic mode the unit automatically
Timer
The unit can be programmed when to start or
stop by using the timer.
• When the unit is switched on, program
• When the unit is switched off, program
Press the Timer button to confirm.
Child lock
The key lock is activated by keeping the Timer
symbol on the touch-screen display pressed
for three seconds. All actions are locked to the
user. The standby symbol flashes every second.
To deactivate the lock, keep the Timer symbol
pressed for three seconds once again.
The lock remains active in the case of a power
failure and also if the remote control is used.
Hotel function
The hotel function disables the dehumidification
mode and Auto functions, leaving cooling,
heating and fan modes active. The setting ranges
are reduced from 22 to 28°C in cooling mode and
from 16 to 24°C in heating mode.
Press the air exchange key for 10 seconds to
enable the function ("En" is shown).
heating and cooling mode and supplies a
90-minute overboost. The unit is then switched
to automatic mode. During the following 30
minutes the Dual Power function cannot be
selected. The Dual Power function is shown
by three flashing speed bars on the display
and the seven red or blue bars moving up and
down of the digital thermometer.
adjusts the speed. The speed is higher
when the difference between the room
temperature and the setpoint is greater, and
then decreases automatically when the room
temperature approaches the setpoint. This
mode is not available in dehumidification
mode or comfort mode night. The Automatic
mode is shown by three speed bars moving up
and down on the display.
the timer to switch off the unit by pressing
the Timer button, followed by the number
of hours (from 1 to 24). Use the up/down
buttons. The unit will switch to standby mode
at the set time.
the timer to switch on the unit by pressing
the Timer button, followed by the number
of hours (from 1 to 24). Use the up/down
buttons. The unit will start at the set time.