6. Fasten the unit to the upper part of the bracket.
7. Verify that the bracket fits securely into the interlocking
points on the unit.
8. Fix the anchor bracket to the wall.
For easier connections, a spacer can be used to keep the
lower part of the unit away from the wall.
Drainage Fig.8.
The unit is supplied with a drip tray for collecting the
condensation which should be channelled to a suitable
place for drainage. The drip tray is fitted with a 0,6 m long
drainage tube with a safety drain. Size and position are
shown on the drilling template and fig.8.
1. Remove the nozzle from drainage tube, or replace the
tube with a longer drainage tube. Be careful not to
squeeze the tube.
2. The whole tube must be coated with anti-condensation
insulation indoors and in the wall.
3. Direct it towards a suitable location for drainage and
keep a downward slope of minimum 3%.
4. Insulate junction points.
If no external drainage is prepared, do not remove the
nozzle from the drainage tube. It is possible to empty
the drip tray using the safety drain. When the drip tray is
full, the unit will stop and error code "OF" appears on the
display. See trouble shooting.
Collecting condensation in a container Fig.8b.
If the condensation is channelled to a water tank, or
similar, it should not be hermetically sealed. Prevent the
end of the drainage tube from immerse in the water.
Open drain Fig.8b.
If the condensation is not collected, check that the
expelled water does not cause any damage or problems
to people or objects. The water could freeze if the outdoor
temperatures are below zero, thus creating a hazard. In
this case, appropriate barriers should be installed in order
to prevent people from approaching the area.
Opening the unit Fig.9.
The unit shold not be opened by any unauthorised
personnel. Opening the unit is only necessary for adapting
it to access the terminal block or to clean the filter.
1. Switch off the power and disconnect the unit.
2. Remove the upper grill by lifting it straight up starting
with the back edge.
3. Remove the air deflector at the front by lifting it by its
upper corners.
4. Remove the filter.
5. Unscrew the four screws securing the upper front panel
and remove the panel. Note! The display is protected by
double-sided tape on the inside of the front.

Electrical installation

Soloclim is equipped with a 1,5 metre long cord with plug
for connection to an earthed power socket. The power
supply should be protected by a circuit breaker 1P+N,
6A, type C. If the cable is damaged it must be replaced
by a qualified service technician. The installation, which
should be preceded by an isolator switch with a contact
Soloclim vertical
separation of at least 3 mm, should only be wired by a
competent electrician and in accordance with the latest
edition of IEE wiring regulations.
Access to the terminal block Fig.9.
Access to the terminal block is only necessary when
replacing the wired cable or when using the CP presence
contact.
1. Switch off the power and disconnect the unit.
2. Remove grille and front panel (see Opening the unit).
3. Unscrew the screws of the terminal block cover and
remove it.
It is possible to remove the unit's cable with plug and
connect the power supply directly to the terminal block.
4. Disconnect the power cord from the terminal block.
5. Connect the power supply, checking that it has
a suitable earth connection and dimensionning
(minimum cable area: 1,5 mm
CP presence contact connection Fig.9.
When the CP contact opens (very low voltage, connected
to a potential free contact) the unit switches to stand-by
mode and CP appears on the display. This contact enables
the connection of an external device such as: prescence
sensor, window opening contact, remote on/off, activation
badge. A double insulation cable should be used. See
wiring diagrams.
Suggestions for saving energy
• Always keep the filters clean.
• Keep doors and windows closed in the air conditioned
room.
• Do not let direct sunlight enter the room (use curtains,
blinds or shutters).
• Avoid using high energy consumption devices in the
room.

Maintenance

The power supply to the unit must be disconnected during
all service, repair and maintenance work. Wait until the
unit is cold.
Housing
To clean the casing, wipe it with a soft, dry cloth. If it is
very dirty, use a slightly damp cloth and, if necessary,
a mild detergent. Wipe afterwards with a dry cloth to
remove moisture.
Filter
Clean the air filter after a period of continuous use and
according to the concentration of impurities in the air,
or when you wish to start-up the unit after a period of
inactivity.
1. Extract the filter, see Opening the unit.
2. Clean the filter with a vacuum cleaner or by washing it
in running water.
3. Allow it to dry completely before putting it back in the
unit.