Original instructions
AR200
FR
.... 28
RU
.... 53
DE
.... 33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Frico AR200 Series

  • Page 1 Original instructions AR200 ..19 ..15 ..28 ..33 ..24 ..43 ..53 ..38 ..48...
  • Page 2: Dimensions And Connections

    AR200 Dimensions and connections AR210/AR215 1002/1512 940/1450 1042/1552 AR210/215A/E DN15 (1/2”) 92/96 AR220 2003 960 (W), 1000 (A/E) 980 (W), 940 (A/E) 2042 1002 AR220A/E...
  • Page 3: Mounting And Installation

    AR200 Mounting and installation Fig. 1: The mounting brackets on delivery. Fig. 2: Mounting on threaded bars. 90° Service hatch Fig. 3: Removal of bottom plate Fig. 4: Function of the snap fixing...
  • Page 4: Minimum Distance

    AR200 Mounting and installation Minimum distance Min 1,8 m Fig. 5 Minimum distance to the floor for AR200E.
  • Page 5 SIReCC615 15 m SIReCC640 40 m SIReCC403 SIReCC405 10 m SIReCC410 SIReUR SIReRTX SIReCC SIReCC415 The air curtain can also be regulated by control box CB30/32N, see www.frico.se. VLSP VKF15LF DN15 VKF15NF DN15 VKF20 DN20 VKF25 DN25 VKF32 DN32 SD230...
  • Page 6 AR200 Wiring diagrams AR200 E SIRe SIReB1XN SIReB1XN F5 F4 H1 N TRANSFORMER MOTOR HEATING ACTUATOR SUPPLY 230V 230V ROOM Parallel connection of multiple units: please see separate SIRe Quick Guide Original instructions Original instructions Original instructions SIRe Competent SIRe Advanced SIRe Basic Quick guide Quick guide...
  • Page 7 AR200 Wiring diagrams AR200 A/W SIRe AR210W AR220W AR215W °C Blue 230V~ 230V~ SIReB1XN SIReB1XN F5 F4 H1 N MOTOR HEATING TRANSFORMER ACTUATOR SUPPLY 230V 230V ROOM...
  • Page 8 AR200 Wiring diagrams AR200 E Switching box (Brass plates) Group 2 AR210E09 AR220E18 AR215E11 Group 1 400V3~ 230V~...
  • Page 9 AR200...
  • Page 10 AR200...
  • Page 11 AR200...
  • Page 12 AR220W 2000 11,5 56,5 0,21 24,9 10,2 33,0 0,12 1400 49,4 0,10 35,2 0,10 ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 13 – = at the current water temperatures and airflows, the air outlet temperature will be less than 35 °C. ) Recommended outlet air temperature for good comfort and optimized output. ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations.
  • Page 14 AR200 Technical specifications | AR200 A without heat 1 Type Output Airflow* Sound Sound Voltage Amperage Length Weight power* pressure* [kW] [dB(A)] [dB(A)] [mm] [kg] AR210A 650/1200 34/50 230V~ 1042 AR215A 950/1750 34/50 230V~ 1552 AR220A 1300/2400 40/54 230V~ 2042 Technical specifications | AR200 E electrically heated 3 Type Output...
  • Page 15: Operation

    Frico mounting and operating For the protection of wider doorways, instructions. several units can be mounted next to each other.
  • Page 16 Note that the unit shall be preceded by a regulating valve, see for instance Frico See wiring diagrams. valve kit. Connections (DN15 (1/2”), inside AR200E:...
  • Page 17: Maintenance

    AR200 the air stream and make it bend inwards Since fan motors and other components into the premises (when the premises are maintenance free, no maintenance are heated and the outdoor air is cold). other than regular cleaning is necessary. The air stream should therefore be The frequency of cleaning can vary directed outwards to withstand the load.
  • Page 18 AR200 Fan replacement If there is no heat, check the following: 1. Determine which of the fans is not • That the heat demand exists; check functioning. thermostat settings and actual 2. Disconnect the cables to the relevant temperature. fan. 3.
  • Page 19 AR200 socket without a safety cut-out, so that the moisture can be eliminated from the element. The drying time can vary from a few hours to a few days. As a preventive measure, the unit should occasionally be run for a short time when it is not being used for extended periods of time.
  • Page 22 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...