easyRAID S4-FWTT User Manual page 43

Table of Contents

Advertisement

Chapter 4 – Setting up an array
A full list of LCD display messages is given in Appendix C
If system power is turned off midway through array initialization, the
process will continue from its point of interruption when power returns.
In a RAID 5+spare array, the disk in the TOP drive carrier is the hot
spare initially. And disk status indicator of the hot spare one will be
shown amber for notification. But after disk hot swapping, the hot spare
disk will be changed. For example: when hot swap disk 3 , then the top
disk (disk 1) will be auto-rebuilt. If you plug disk 3 afterward, disk 3 will
be the new hot spare disk, it's no longer the TOP disk. It can be
recognized by disk status indicator.
-4-7-

Advertisement

Table of Contents
loading

Table of Contents