easyRAID S4-ESTT
eSATA (1.5Gb) to Serial ATA
Disk Array System
User Manual
Version 1.0

Advertisement

Table of Contents
loading

Summary of Contents for easyRAID S4-ESTT

  • Page 1 S4-ESTT eSATA (1.5Gb) to Serial ATA Disk Array System User Manual Version 1.0...
  • Page 3 S4-ESTT eSATA (1.5Gb) to serial ATA Disk Array System User Manual...
  • Page 5 Important Safety Instructions, Care and Handling Before starting, take a few minutes to read this manual. Read all of these instructions and save this manual for later reference. Protect the disk array system from extremely high or low temperatures. Let the disk array system warm (or cool) to room temperature before using it.
  • Page 6 The appliance must be grounded. The disk array system is equipped with a 3-wire grounded type of power cord. This power cord will only fit into a grounded type of power outlet. If an extension cord or a power center is used with the disk array system, make sure that the total current con- sumption of all products plugged into the wall outlet does not exceed the ampere rating.
  • Page 7: P P R R E E F F A A C C E E

    Preface Notice Product features and specifications described in this manual are subject to change without notice. The manufacturer shall not be liable for any damage, or for the loss of information resulting from the performance or use of the information contained herein. Trademarks This manual has been checked for accuracy, but no guarantee is given that the contents are correct.
  • Page 8: Regulatory Information

    User’s Manual Regulatory information For Europe This equipment is in conformity with the EMC directive. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Those limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 9 Preface UL Listed This equipment meets UL's safety requirements. - 3 -...
  • Page 10: Intended User

    User’s Manual About this manual Intended user This manual is designed and written for users of the subsystem. This is an entry level product suitable for most users. Organization of the manual This manual consists of the following sections: Chapter 1: Introduction provides an overview of the as well as details of key features and a list of specifications.
  • Page 11: Using This Manual

    Preface Using this manual This guide contains all the information you need to set up and start using your subsystem and to monitor its performance in real time. The setup process will follow these steps: Familiarize yourself with the features and capabilities of Prepare: (Chapter 1) Decide whether to set up a RAID 0, 0+1, 5 or 5+spare array...
  • Page 12: Guide To Conventions

    User’s Manual Guide to Conventions Important information that users should be aware of is indicated with the following icons: This icon indicates the existence of a potential hazard that could result in personal injury, damage to your equipment or loss of data if the safety instruction is not observed.
  • Page 13: Table Of Contents

    Contents E ....................1 ........................... 1 OTICE ....................2 EGULATORY INFORMATION Intended user........................4 Organization of the manual .................... 4 ....................... 5 SING THIS MANUAL ......................6 UIDE TO ONVENTIONS S ................I CHAPTER 1 ....................1 N .................. 1-1 ...........................1-1 VERVIEW ........................1-2...
  • Page 14: T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S

    User’s Manual RAID ......................4-2 ETTING LEVEL Setting RAID 0......................4-4 Setting RAID 0+1......................4-4 Setting RAID 5......................4-4 Setting RAID 5+spare ....................4-4 ......................4-5 REATING AN ARRAY Over 2TB capacity....................... 4-6 ................4-7 HECKING THE STATUS OF SUBSYSTEM ..................
  • Page 15: Chapter 1

    Chapter 1 – Introduction This chapter introduces the features and capabilities of subsystem. You will find: A full introduction to your subsystem Details of key features A list of the product specifications Overview Congratulations on your selection of the subsystem. The subsystem is a high-performance and extremely flexible RAID subsystem.
  • Page 16: Key Features

    User’s Manual Key features The subsystem supports the following features Automatic on-line rebuilding Drives are hot swappable Supports RAID levels 0, 0+1 and 5 Optional hot spare setup for RAID 5 (5+spare) Hot swappable fan Supports four Serial ATA hard drives Requires no driver Audible alarm on drive failure &...
  • Page 17 Chapter 1 – Introduction This manual contains the information necessary to set up each of the two available hardware configurations of the subsystem . Where procedures for the configurations differ, they are described separately and clearly marked. - 1-3 -...
  • Page 18: Specifications

    User’s Manual Specifications Available host intefaces and transfer speeds eSATA 1.5Gb Disk Interface Support Four SATA1 1.5Gb disk interfaces and compatible with SATA2 3Gb disks RAID Function Support Hardware RAID level 0, 5, 0+1, 5 + spare by switch setting Hot swappable disk Automatic on-line rebuilding Subsystem Function Support...
  • Page 19: Mechanical, Environmental And Safety Specifications

    Chapter 1 – Introduction Mechanical, Environmental and Safety Specifications Dimensions: 286.5(L) x152.8(W) x 206.4(H) (mm) Host Connectors (depending on hardware configuration): One eSATA connector Interface Connectors: One RS-232 connector Operation temperature: 0 ~ 35℃ Operation humidity: 5 ~ 95 %, non-condensing Storage humidity: 5%~95%, non-condensing 200 W power supply 100~264V(+/-10%),47~63Hz...
  • Page 21: Chapter 2

    Chapter 2 – Before you begin This chapter includes all the information you need to prepare for installation and to decide which RAID level to use. You will find: A checklist of what should be in the product package A full introduction to and comparison of RAID levels 0, 0+1 and 5 Important notices on the safe operation and installation of Making sure you have everything...
  • Page 22: What Else You Need

    User’s Manual The following cables: Power cable eSATA cable Screws pack Drive lock keys (x2) User Manual What else you need In order to setup a working system, the following user-supplied items are required: Host computer system with eSATA interface Four disk drives For non-proprietary accessories, such as cables, etc., ask your vendor to recommend compatible and reliable brands.
  • Page 23: Pre-Installation Planning

    Chapter 2 – Before you begin Pre-installation planning Introduction to RAID levels The can support the following RAID levels: 0, 0+1 and 5 with the additional option of RAID 5 + hot spare. Which is the right level for you? The answer depends on the application it is used for.
  • Page 24 User’s Manual RAID 0: Striped disk array without fault tolerance Characteristics: Recommended use: RAID 0 implements a striped disk array, the Video production and data is broken down into blocks and each editing block is written to a separate disk drive. Image editing I/O performance is greatly improved by Pre-press applications...
  • Page 25: Raid 0+1

    Chapter 2 – Before you begin RAID 0+1 RAID 0+1 combines mirroring and striping functions on a minimum of four hard disks. Mirroring provides full redundancy and protects data in case of multiple drive failure (providing that data on one of each mirrored pair of drives is intact). RAID 0+1: Combination of mirroring and striping Characteristics: This configuration provides optimal speed and reliability.
  • Page 26: Raid 5 And Raid 5+Hot Spare

    User’s Manual RAID 5 and RAID 5+hot spare RAID 5 uses a mathematical expression that compares data from three drives and calculates a fourth piece of data called “parity” which is saved on a fourth drive. Should one of the drives fail, parity data can be used to rebuild the failed data. Under RAID 5, parity data is stored across all drives in the array.
  • Page 27 Chapter 2 – Before you begin The diagram below represents the writing of data on a RAID 5 array composed of four DISKS connected to the controller. Parity blocks are represented by the letter P. - 2-7 -...
  • Page 28 User’s Manual The diagram below represents the writing of data on a RAID 5+hot spare array composed of four DISKS connected to the controller. Parity blocks are represented by the letter P. Arrangement of data and parity blocks saved on a Level 5+hot spare RAID - 2-8 -...
  • Page 29: Pre-Installation Notices

    Chapter 2 – Before you begin Pre-installation notices Before starting any kind of hardware installation, please ensure that all power switches have been turned off and all power cords disconnected to prevent personal injury and damage to the hardware. To avoid overheating, should be installed in a well-ventilated area and in such a way that sufficient airflow is maintained across the controller chips.
  • Page 31: Chapter 3

    Chapter 3 – Setting up the subsystem This chapter gives an overview of the subsystem and explains how to: Remove the drive carriers from the subsystem Load hard drives into the drive carriers Install the drive carriers in subsystem Familiarizing yourself with This manual contains the information necessary to set up the available hardware configurations.
  • Page 32: Front View

    User’s Manual Front view Drive carriers Each drive carrier can hold a one-inch high 3.5-inch form factor SATA disk drive. LCD Display The LCD displays status and configuration information for the subsystem and arrays. A full list of LCD display messages is given in Appendix C.
  • Page 33: Rear View

    Chapter 3 – Setting up the subsystem Rear view Power switch The power switch is the main on/off switch of the subsystem. Fan vent The fan vent should be kept unobstructed. RAID level selector The RAID level selector consists of two switches which together are used to set the RAID level.
  • Page 34: Loading Drives Into

    User’s Manual Loading drives into The subsystem should be fitted with four hard disk drives. Load each drive into a drive carrier as follows: 1. Pull the drive carrier handle to release the latch. 2. Slide the drive carrier out of the subsystem.
  • Page 35: Chapter 4

    Chapter 4 – Setting up an array This chapter explains how to: Set RAID level Create an array Remove and replace drives from an array Connect subsystem to a host computer Set the time and date Array creation flowchart Setting up an array is simple. This chapter will lead you through the following steps: Set RAID Use the RAID level selector to set the RAID level (0, level...
  • Page 36: Setting Raid Level

    User’s Manual Setting RAID level RAID level is set using the RAID level selector on the rear panel of the subsystem. The RAID level selector consists of two switches. The four possible combinations of switch position correspond to the four available RAID settings: 0, 0+1, 5 and 5+spare.
  • Page 37 Chapter 4 – Setting up an array The subsystem must be switched off to change RAID level. To change RAID level: Power off Set the new RAID level using the RAID level selector Remove all four disks Power on Install the four disks to start RAID initialization Changing RAID level may lead to the loss of all data on the array.
  • Page 38: Setting Raid 0+1

    User’s Manual Setting RAID 0 1. Ensure is turned off. 2. Move both selector switches 1 and 2 to ON as shown. Setting RAID 0+1 1. Ensure is turned off. 2. Move selector switch 1 to ON and 2 to OFF as shown Setting RAID 5 1.
  • Page 39: Creating An Array

    Chapter 4 – Setting up an array Creating an array To create (initialize) an array: 1. Ensure that four drives are installed. 2. Ensure that the RAID level selectors are correctly positioned for the desired RAID level. 3. Connect a power cable. 4.
  • Page 40: Over 2Tb Capacity

    User’s Manual The RAID capacity determined on the RAID level and the capacity of drives you installed in , for an example: If configuring as R5 and install 4 drives each of them are 10 GB, 20 GB, 30 GB, 40 GB to create an array then the total RAID capacity will be 30 If a red disk status indicator shows, check to make sure the appropriate drive is: Locked Installed correctly...
  • Page 41: Checking The Status Of Subsystem

    Chapter 4 – Setting up an array If system power is turned off midway through array initialization, the process will continue from its point of interruption when power returns. Checking the status of subsystem The status of the subsystem and array is given by the LCD display. Press the scroll button to the left of the display to scroll through information about the array.
  • Page 42: Removing / Replacing A Drive

    User’s Manual Removing / replacing a drive What if a disk fails? If a disk drive fails, the disk status indicator of the disk carrier will light red and the alarm will sound. When this happens, you should replace the failed disk. The failure or removal of a single drive in a RAID5 array will not lead to failure of the array.
  • Page 43: Removing A Drive

    Chapter 4 – Setting up an array Removing a drive 1. Pull the drive carrier handle. 2. Slide the drive carrier out of the subsystem. 3. Remove four screws from the tray and lift out the disk drive. - 4-9 -...
  • Page 44: Connecting To A Host Computer

    User’s Manual Connecting to a host computer Once the array is initialized, you can connect subsystem to a host computer. The RAID cannot be recognized by Operating System before initialization complete. To connect to the host: 1. Power on subsystem and follow the instructions earlier in this chapter to establish a RAID array.
  • Page 45: Setting The Display Time & Date

    Chapter 4 – Setting up an array Setting the Display Time & Date Press down the right hand (Enter) button for over five seconds to enter or change the time and date displayed on the display. When you release the button, the date and time setting screen will show: YY/MM/DD HH:MM 1.
  • Page 47: Chapter 5

    Chapter 5 – Partitioning the array This chapter explains how to partition the array in Windows , Linux and Mac OS X operating systems. Partitioning the array - Windows The array must be partitioned before it can be used. To do this on a Windows operating system: 1.
  • Page 48 User’s Manual 6. Right click on the disk representing the array and select Create Partition. Follow the wizard to create one or more partitions on the array. 7. When you have completed creating a partition, the array will appear as a disk in the disk management section of the Computer Management dialog box.
  • Page 49: Partitioning The Array - Linux

    Chapter 5 – Partitioning the array Partitioning the array - Linux The array must be partitioned before it can be used. To do this on a Linux operating system: 1. Establish the array and connect to the host computer following the instructions in the preceding chapter.
  • Page 50 User’s Manual 6. Enter the command to add a partition (in the example given, the command is “n.”) 7. Enter the command to create a primary partition then enter the number of primary partitions you wish to create. 8. Enter the command to create a Linux second extended file system on the array.
  • Page 51: Partitioning The Array - Mac Os X

    Chapter 5 – Partitioning the array Partitioning the array – Mac OS X The array must be partitioned before it can be used. To do this on a Mac operating system: 1. Establish the array and connect to the host computer following the instructions in the preceding chapter.
  • Page 52 User’s Manual 6. The confirmation dialog will be pop out to confirm again. Click Partition to continue procedure. 7. The partition will then begin, and process is been showing as creating partition map in lower right corner of dialog box. 8.
  • Page 53 Chapter 5 – Partitioning the array - 5-7 -...
  • Page 54: Partitioning The Array - Vista

    User’s Manual Partitioning the array – Vista The array must be partitioned before it can be used. To do this on a Windows Vista operating system: 1. Right click Computer and click Manage. 2. From the Computer Management window, select Disk Management.
  • Page 55 Chapter 5 – Partitioning the array 8. Your drive should now appear in your Computer and ready for use. - 5-9 -...
  • Page 57: F F A A Q Q

    Appendix A – FAQ If you encounter a problem while using the subsystem, check this section for help. 1. My Operating System is Linux. I have enabled the over 2TB capacity setting, but I still cannot partition a device over 2TB in OS. Why? The subsystem is over 2TB available, but most OS still cannot support SATA device to over 2TB capacity.
  • Page 58 User’s Manual or (2) Re-plug the four disks and re-create the Array to R0 (But data in the R5 disks will be lost due to the destructive init ) If I really want to re-create a new RAID. How should I do? Remove all disks.
  • Page 59 Appendix A – FAQ 11. Three disks have failed. What should I do? Swap the single functioning disks with each of the failed disks in turn. If the functioning disk continues to function at its new location, the original disk was faulty and should be replaced.
  • Page 60 User’s Manual Example: <2134>: disk 2 and disk 1 sequence is reversed. <13x4>: the original disk 3 is put into tray 2 and the original disk 2 is not plugged or failed. Condition 3 R A I D F a i l C o d e : 2 Note: The RAID has been failed but all of 4 disks exist.
  • Page 61: G G L L O O S S S S A A R R Y Y

    Appendix B– Glossary Array See Disk Array. Array Management Software The body of software, that provides common control and management for a disk array. Array Management Software most often executes in a disk controller or intelligent host bus adapter, but may also execute in a host computer. When it executes in a disk controller or adapter, Array Management Software is often referred to as Firmware.
  • Page 62 User’s Manual Parity Parity information is redundancy information calculated from actual data values. If any single piece of data is lost, the data remaining and the parity information can be used together to compute the lost data. Parity information can either be stored on a separate, dedicated drive, or be mixed with the data across all the drives in the array.
  • Page 63: L L C C D D D D I I S S P P L L A A Y Y M M E E S S S S A A G G E E S S

    Appendix C – LCD Display Messages When the system power is turned on, the following message will be always first displayed: If the system installs 4 disks with a RAID level, this message will be next. Over 2TB capacity setting If you would like to enable the function of support over 2TB capacity, press the button “ENT”...
  • Page 64: Raid Initialization

    User’s Manual RAID initialization Create new RAID When the system is powered on and it’s ready, replace 4 disks, the following message will be displayed to ask user to confirm the initialization process. User can press the MENU or ENTER button to select NO or YES to confirm your selection and move to the next operation.
  • Page 65: System Ready

    Appendix C – LCD Display Messages RAID initialization failed If there is any disk error happens on one of the 4 disks, for example disk 2, the LCD will display one of the following two messages respectively for disk failure or bad sectors detected: System ready After the system is powered on with all 4 disks successfully initialized, it will display the following message:...
  • Page 66: Disk Information: Mode, Capacity

    User’s Manual Disk information: mode, Capacity Repeat messages 6.2.5.1 to 6.2.5.3 until all 4 disks information being displayed System firmware version: System serial number: System fan speed and temperature: 。 Error and failure messages Error or failure messages will be displayed on LCD panel under the following conditions: Disk failure message: if one of the 4 disks fails in the operation - C-4-...
  • Page 67 Appendix C – LCD Display Messages Disk bad sector messages “DISK x bad Y”: It means disk x has Y bad sector. “Total bad xx”: it means total xx bad sectors had have. If the DISK has more than 8 sector, the subsystem will beep to let the user know how bad of the drive.
  • Page 68 User’s Manual Examples: <2134>: disk 2 and disk 1 sequence is reversed. <13x4>: the original disk 3 is put into tray 2 and the original disk 2 is not plugged or failed. <423s>: the spare disk is put in the tray 4 and original disk 4 is put in the tray 1 “Code 2”...
  • Page 69: Where The Speed Of Failed Fan Is 100 Rpm

    Appendix C – LCD Display Messages Fan failure message: fan can not function normally Where the speed of failed fan is 100 rpm Overheat message: will be displayed when temperature > 50 。 。 > Disk shut down message: will be displayed when temperature > Disk rebuilding messages The system will display the disk rebuilding progress when a failed disk is replaced by a new one.
  • Page 70: Time Setting

    User’s Manual If there are too many bad sectors detected in the newly installed disk during rebuilding process, the LCD panel will display the following message. If the newly installed disk can not be accessed (and thus fails), the LCD panel will display the following message. Time setting After the Enter button is pushed for over five seconds and released, the following message will be displayed for users to change the time...
  • Page 71: Appendix D

    Appendix D – Updating Firmware The subsystem is shipped with firmware installed. You may however wish to install new or upgraded editions of the firmware. Ask your vendor about the latest firmware edition. Once new or updated firmware has been obtained, it can be downloaded to from a host PC with third party communication software, such as HyperTerminal, that supports ANSI terminal emulation.
  • Page 72 User’s Manual 3. Launch HyperTerminal from the desktop of the host computer (Start > Programs > Accessories > Communications > HyperTerminal). 4. The Connection Description dialog box will appear (if this is the first time you have run HyperTerminal, you will first be prompted to enter information about your location).
  • Page 73 Appendix D – LCD Display Messages === Download Mode ====== ******Choose 8. Turn on subsystem and press "1" to download firmware. Esc on the host computer keyboard. The >>>>> prompt will appear. Enter '1' to Download Firmware 9. Type in the 'ESC' exit command ”download”.