If a red disk status indicator shows, check to make sure the appropriate drive is:
Locked
Installed correctly
Not faulty (if necessary, the drive should be replaced).
Initialization of an array may take up to 15 minutes depending on the capacity of disks
and the RAID level selected.
The status of the controller and array is given by the LCD display. Press the scroll button
to the left of the display to scroll through information about the array. The following
information is available:
The RAID capacity determined on the RAID level and the capacity of
drives you installed in , for an example:
If configuring as R5 and install 4 drives each of them are 10 GB, 20 GB,
30 GB, 40 GB to create an array then the total RAID capacity will be 30
GB.
The alarm will sound in case of RAID failure. Press the Enter / Mute
button to the right of the display to silence the alarm.
RAID level and Capacity
Disk model
Disk DMA mode and capacity
Firmware Version
Serial Number
Fan Status and Temperature Status