LTPH-UM-1149-01
L
A
OOP
TTENUATION
Each loop has no more than 35 dB of insertion loss at 196 kHz, with driving and terminating impedances of 135 Ω ,
as shown in
Table 27
Cable Gauge
26/0.4 mm
24/0.51 mm
22/0.61 mm
19/0.91 mm
(a) Insertion Loss = 1.25 times loop attenuation
H2TU-C-231 L
* Fuse alarm is normally floating and at -48 Vdc when activated.
** Active pins are solid black.
H2TU-C-231 List 3F
below. This is equivalent to no more than 28 dB loop attenuation.
Table 27. HDSL2 Reach Chart
(a)
Insertion Loss
at
196 kHz (dB/kft)
3.88
2.84
2.18
1.54
3F C
-E
IST
ARD
DGE
Tip
Ring
HDSL2 Span
Fuse alarm
*
-48 Vdc
DSX-1
Tip
XMT (IN)
Ring
Ground
Management bus
Tip 1
DSX-1
RCV (OUT)
Ring 1
Figure 34. H2TU-C-231 List 3F Card-Edge Connector
Loop Attenuation
Maximum Reach
(dB/kft)
3.1
2.2
1.7
1.2
C
ONNECTOR
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
KEY
KEY
38
13
39
14
40
15
16
41
42
17
Ground
43
18
44
19
45
20
46
21
47
22
48
23
Factory use only
49
24
50
25
June 12, 2002
Appendix A - Specifications
Ω
per kft
(kft)
9
83
12
52
16
32
23
16
63