Manual Loopback Session; Setting The Loopback Time-Out Option; Activating Manual Loopback Mode - ADC HiGain H2TU-C-231 List 3F User Manual

Line unit
Hide thumbs Also See for HiGain H2TU-C-231 List 3F:
Table of Contents

Advertisement

Testing
M
L
ANUAL
OOPBACK
A manual loopback session allows for any HDSL2 loopback selection as listed in
exception of SmartJack loopbacks, which can only be issued by inband commands.

Setting the Loopback Time-Out Option

Before initiating a loopback session, verify that the Loopback Time-Out parameter is set to the desired setting.
Table 5 on page 16
describes this option.
1
Log on to the maintenance terminal.
2
Select Config, Standard Options, then LBTO.
3
Verify the LBTO setting.

Activating Manual Loopback Mode

With the exception of SmartJack, any of the HDSL2 loopbacks can be executed using the MODE
and LBK pushbuttons.
When executing a manual loopback session using the MODE and LBK pushbuttons:
The next loopback option can be displayed by pressing the MODE pushbutton, however, the
previously activated loopback remains active until the LBK pushbutton is pressed, which
activates the new loopback.
If neither pushbutton is pressed for a period of 30 seconds and no loopback is in effect, the
manual loopback session terminates, and the display returns to normal mode.
If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the
manual loopback sessions continue until the loopback times out in accordance with the
LBTO setting.
If there is an active loopback, pressing the MODE and LBK pushbuttons for 5 or more
seconds terminates any active loopback, ends the manual loopback session, and returns the
display to normal mode.
To initiate a manual loopback session:
1
Press both the MODE and LBK pushbuttons on the front panel for at least 3 seconds. The following message
appears on the front-panel display:
MAN LPBK NLO?
2
Press LBK to activate NLOC. The display changes to MAN LPBK NLOC.
3
Press MODE to advance to the next available loopback:
NRE? = NREM
CRE? = CREM
CLO? = CLOC
COL? = dual loopback at H2TU-C.
RUL? = dual loopback at H2TU-R.
4
Press LBK to activate the selected loopback. The previous loopback is terminated.
Once a loopback is selected and activated, the loopback stays active until it times out (based on the LBTO setting).
When a loopback times out, the display then returns to the normal display mode.
54
S
ESSION
June 12, 2002
LTPH-UM-1149-01