Testing
Testing with the H2TU-R Signal Generator
Monitor
Performance
Use <Spacebar> to cycle through option settings and <Enter> to activate
ID: xxxx--xxxx--xxxx-xxxx
The H2TU-R Signal Generator screen allows transmission of a test signal from the H2TU-R toward either the CI
or the network.
1
Press
R
to logon remotely, then press
2
Use the
↑
and
↓
3
Use the arrow keys to select an option and press the
to
Table 25
for a list of signal generator option settings.
4
Press
ENTER
to activate your choice.
5
Press
R
to return to the H2TU-C logon screen. You can exit the Signal Generator screen while signal
generation is active.
Option
Test Signal Generator
Test Signal Pattern
Test Signal Linecode
Test Signal Direction
Test Signal Framing
60
Event Log
Config
+-----------------------+
| Standard Options
| ADC Options
|
Signal Generator
+--------------------------------------+
| Test Signal Generator
| Test Signal Pattern
| Test Signal Linecode
| Test Signal Direction
| Test Signal Framing
+--------------------------------------+
04/10/2002 13:38:31
Figure 33. H2TU-R Signal Generator Screen
C
to select the Config menu.
arrow keys to select Signal Generator and press
Table 25. Signal Generator Option Settings
Settings
On or Off
All ones, all zeroes, 2
20-1
2
1:8 pattern, 2:8 pattern, 3:24 pattern
AMI or B8ZS
Toward CPE or toward NET & CPE only
SF, ESF, or UNFR
June 12, 2002
Inventory
Report
-> |
-> |
->
|
:
: ALL 1
: AMI
: NET + CPE
: SF
H2TU-R
ENTER
SPACEBAR
to cycle through the available settings. Refer
23-1
pseudo random,
15-1
pseudo random, 2
pseudo random,
LTPH-UM-1149-01
Rlogon
Help
OFF
|
|
|
|
|
System: OK
.
H2TU-C-231 List 3F