Gree GWH09ACC-K6DNA1F/I Service Manual page 24

Hide thumbs Also See for GWH09ACC-K6DNA1F/I:
Table of Contents

Advertisement

Heating:
Rated heating condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
20/-
7/6
20/-
7/6
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Technical Information
Pressure of gas pipe connecting
indoor and outdoor unit
Model
P (MPa)
9K
2.8~3.2
12K
2.2~2.4
18K
2.2~2.4
24K
2.2~2.4
Inlet and outlet pipe temperature of
heat exchanger
T1 (°C)
T2 (°C)
63 ~ 35
2 ~ 5
70 ~ 35
2 ~ 4
70 ~ 40
1 ~ 5
70 ~ 35
2 ~ 4
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Super High
High
Super High
High
21