Step
4. Remove front panel assy
Remove connection screws connecting the front panel
assy with the chassis and the motor support, and then
remove the front panel assy.
5. Remove right side plate assy
Rescrew the ground screws, remove the ground wires,
loosen the screws fixing terminal board, remove the
terminal board, rescrew the screws fixing the right
plate, and remove the right side plate assy.
6. Remove valve suppprt
Remove the valve support bolck, remove the screws
fixing valve support, remove the screws fixing the liquid
valve and gas valve then remove the valve support.
Installation and Maintenance
Procedure
Front Panel Assy
Right Side
Plate Assy
valve supprt
Valve Support Block
105