Klein Tools CL120KIT Instruction Manual page 8

400a ac auto-ranging digital clamp meter
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
WIRING CONFIGURATION TESTING
Conditions indicated: wiring correct, open ground, reverse polarity,
open hot, open neutral and hot/ground reversed.
Conditions NOT indicated: quality of ground, multiple hot wires,
combinations of defects, reversal of grounded and grounding
conductors.
All appliances or equipment on the circuit being tested should be
unplugged to help reduce the possibility of erroneous readings.
STANDARD RECEPTACLES
1. Verify tester operation by testing on a known live and correctly
wired receptacle.
2. Plug tester into receptacle.
3. Compare the illuminated lights on the tester to the key code
printed on the tester.
4. If the tester indicates that the receptacle is not wired correctly,
consult a qualified electrician.
GFCI RECEPTACLES
1. Check the GFCI receptacle user manual for information on how the
specific receptacle operates prior to using this tester.
2. Insert the tester into the receptacle under test to check for
correct wiring (See FIG. 1). Lights on the tester should
illuminate.
3. Press the "TEST" button on the GFCI receptacle.
Did the GFCI trip and the lights on the tester go dark?
YES: Reset the GFCI by pressing the reset button. Proceed to
step 4.
NO: The GFCI is not operating properly or the receptacle is
miswired. Consult a qualified electrician.
4. Press and hold the test button on the tester for 7 seconds. Did the
GFCI trip and the lights on the tester go dark?
YES: Reset the GFCI by pressing the reset button. The GFCI
appears to be operating properly.
NO: The GFCI is not operating properly or the receptacle is
miswired. Consult a qualified electrician.
Wipe with a clean, dry lint-free cloth. Do not use abrasive
cleaners or solvents.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov/recycle for additional
information.
14
CLEANING
DESCRIPTION
The Line Splitter 10x assists in measuring the current draw of a
connected load such as an electrical device or appliance up to 15A
without splitting the device or appliances power cord. It has been
designed for use with Klein Tools clamp meters, but will also function
with many other manufacturers' clamp meters.
GENERAL SPECIFICATIONS
Relative Humidity: < 85% non-condensing
Operating Temperature: 32° to 122°F (0°C to 50°C)
Storage Temperature: -4° to 140°F (-20°C to 60°C)
Dimensions: 4.67" x 2.28" x 1.22" (119 x 58 x 31 mm)
Nominal Voltage: 110/125V AC at 50/60Hz in 3-wire outlet
Weight: 3.2 oz. (90.7 g)
Drop Protection: 3.3 ft. (1 m)
Maximum Load Current: 15A
Measurement Correction: Clamp Meter will display 10x actual
current, eg. Actual current of 1.5A will be displayed as 15A on
clamp meter when using Line Splitter 10x.
• Read, understand, and follow all warnings and instructions before
operating this device. Failure to follow instructions could result in death or
serious injury.
• Do NOT use with current loads greater than 15A (which would be displayed
as greater than 150A on a clamp meter using the Line Splitter 10x).
• Risk of electric shock and burn. Contact with live circuits could result in
death or serious injury.
• Do not use if Line Splitter 10x appears damaged in any way, if in doubt,
replace Line Splitter 10x.
• Always wear approved eye protection.
• Do NOT use Line Splitter 10x if wet.
• Intended for indoor use only.
• Always consult a qualified electrician to resolve wiring problems.
FIG. 2
Receptacle
69409
WARNINGS
Clamp Meter
Line Splitter 10×
Load
15

Advertisement

Table of Contents
loading

Table of Contents