8.
Non Contact Voltage (NCV): > 25V AC
PRESS
PRESS
and
and
HOLD
HOLD
1200
Symbols USED ON LCD
~
AC Measurement
DC Measurement
-
Negative DC Value
AT
Auto Range Active
O.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
MAX
Minimum Reading
Maximum Reading
%
Duty Cycle Mode
Frequency Mode
V
Voltage Measurement
A
Current in Amps
Resistance in Ohms
Diode Test
F
Capacitance in Farads
Continuity Test
n
µ
Nano 10
-9
Micro 10
-6
m
k
Milli 10
Kilo 10
-3
3
M
Mega 10
6

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 600V
0.1mV ˜ 100mV
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload Protection:
1000V
AC Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 750V
0.1mV ˜ 1V
± (2.0% + 5 digits)
Overload Protection:
750V RMS
Frequency Response:
45 to 400 Hz
Minimum Voltage for Frequency Measurement:
200mV
Response:
Averaging
DC Current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (1.2% + 3 digits)
2000µA
1µA
Overload Protection:
Voltage:
600V RMS
Current (leads):
2000µA
AC Current Measurement
Range
Resolution
Accuracy
600µA
0.1µA
± (2.0% + 5 digits)
2000µA
1µA
± (1.5% + 5 digits)
60A
0.01A
± (2.9% + 15 digits)
600A
0.1A
± (1.9% + 8 digits)
Overload Protection:
Voltage:
600V RMS
Current: (leads)
2000µA
(clamp)
600A
Frequency:
45 to 400Hz
Minimum Current for Frequency Measurement:
400µA or 20A
Minimum Current for Clamp Measurement: 0.2A
Response:
Averaging
Resistance Measurement
Range
Resolution
Accuracy
600 Ω ˜ 6M Ω
0.1 Ω ˜ 1k Ω
± (1.0% + 4 digits)
60M Ω
10k Ω
± (2.0% + 4 digits)
Overload Protection:
600V RMS
Capacitance Measurement
Range
Resolution
Accuracy
60nF ˜ 6000µF
0.01nF ˜ 1µF
± (3.5% + 6 digits)
Overload Protection:
600V RMS
Frequency Measurement (Voltage)
Range
Resolution
Accuracy
99.99Hz ˜ 499.9kHz
0.01Hz ˜ 100Hz
± (0.1% + 4 digits)
Overload Protection:
600V RMS
Sensitivity:
2.5V RMS
Duty Cycle Measurement
Range
Resolution
Accuracy
1 ˜ 99%
0.1%
± (0.1% + 5 digits)
Overload Protection:
600V RMS
Sensitivity:
1.2Vpp ~ 50Vpp
Frequency Range:
< 500 Hz
Diode Test
Overload Protection Range
Test Current
Open Circuit Voltage
< 1.8V DC
600V RMS
6.0V
Appx. 0.25mA
Continuity Test
Overload Protection
Open Circuit Voltage
Threshold (Appx.)
600V RMS
< 0.44V
<40Ω
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
Specifications subject to change.
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items
must be properly disposed of in accordance with local regulations.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
customerservice@kleintools.com
www.kleintools.com
139701 Rev. 01/14 B
CL1200
Instruction Manual
ENGLISH
• DATA HOLD
• BACKLIGHT
• WORKLIGHT
• ANALOG
BAR GRAPH
• MAX / MIN
1200
• 3-5/6 DIGIT
5999 COUNT LCD
• AUTO / MANUAL
RANGE
• NON CONTACT
VOLTAGE TESTER
750V
1000V
600A

Advertisement

loading

Summary of Contents for Klein Tools CL1200

  • Page 1 600V RMS < 0.44V <40Ω Minimum Voltage for Frequency Measurement: 200mV Response: Averaging CUSTOMER SERVICE Non Contact Voltage Detector DC Current Measurement KLEIN TOOLS, INC. On Voltage Range Resolution Accuracy 450 Bond Street Appx. 25V AC Lincolnshire, IL 60069 600µA 0.1µA ±...
  • Page 2 GENERAL SPECIFICATIONS Magnetic Back • Attach instrument to metal for hands-free use. The Klein Tools CL1200 is an auto-ranging clamp meter. It measures Bar Graph AC / DC voltage, AC current, resistance, capacitance, frequency and duty • The bar graph shows an approximate analog representation Hz/Duty cycle.