System Startup and Flushing Process ........ 11 INTRODUCTION Leveraging proprietary technology, the Pentair® Everpure® EZ-RO system provides high quality water for applications, such as premium espresso, coffee, ice, and blended beverages. The system combines multiple water treatment technologies, providing superior protection against taste and odor-causing contaminants. The system meets espresso, coffee, ice, and...
Membrane Filter The Pentair EZ-RO system includes all the necessary fittings for installation except for an air gap for the waste water. Lengths of 1/4", 3/8", and 1/2" tubing have been provided. The Pentair EZ-RO system is packaged as a complete unit in two cartons. You should have the following:...
Make sure O-rings are in correct location in fitting. Insert tubing past both O-rings until it comes to a hard stop. 8 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 9...
NSF testing completed at influent water conditions of 750 PPM TDS and at 50 PSI water, using reject flow restrictor as indicated. Inlet valve: top black handle pointed down (open). Outlet valve: bottom black handle pointed to right (closed). 10 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 11...
20. Pressure should drop to 0 psi. IMPORTANT: Bring pressure down to 0 psi before attempting filter changes. 19 19 12 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 13 Proof April 18, 2022...
RO water distribution piping. The size of the blended water tubing/piping should be 1/2- inch (12.7 mm) O.D. minimum. 14 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 15...
• Water will run from the reject line and tank sampling valve. 12. Flush pre-filter and mineral cartridge for 10 minutes or until water runs clear. 16 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 17...
Page 10
However, you may need to recalibrate based on your needs, as well as from time-to-time to ensure best results. 18 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM | 19...
Membrane failure Measure TDS out of permeate sample port. Measure reject flow rate. Replace Tel: 800.942.1153 (US Only) • 630.307.3000 Main • Email: servicespecialist@pentair.com prefilter and RO membrane as needed. Check to see if the capillary flow control is plugged. Replace capillary flow control as needed.
DIMENSIONS 8.0" REPLACEMENT PARTS 18.0" Contact your local Pentair® Everpure® distributor for system replacement parts. To locate your distributor, call customer Wall Mounted Processor Processor on Optional Stand service at 800.942.1153 or 630.307.3000. 18.0" 18.0" CANISTERS OPTIONAL STAND KIT PART EV315928...