5. Turn on the engine.
6. When the LED lights up RED or ORANGE, the
charge starts.
7. Check the leisure battery voltage with the voltmeter
and compare it to the previous measurement. The
voltage must be higher then before.
8. After 2 minutes verify with a Clamp Meter that the
POWERSERVICEPSB
declared (this phase could last a few seconds if the
leisure battery is completely charged).
9. With a voltmeter check the Starter battery voltage
to the battery poles, and compare it the voltage
between
Ref.C (fig.1) and the negative one Ref.A (fig.1): the
difference between the two connections should be
0.7V maximum. If the voltage difference is higher
then 0.7V, please use a larger cross section cable to
connect to
the starter battery. It may also be necessary to
improve the ground (GND) connection (Ref.C).
During this phase always take the measurement
while the engine is running.
17.MAINTENANCE
We periodically recommend:
• Clean the external surface to prevent the dust and dirt
accumulation.
• Check that the input connections and the battery
poles are tight and secure.
• Make sure that the ventilation slots are not obstructed
by dirt or any material.
POWERSERVICEPSB
POWERSERVICEPSB
maximum current data are as
24
Positive Terminal
Terminal Ref.A to

Advertisement

loading