14.EXTERNAL FUSE
External fuses must be installed very close to the
battery poles. The characteristics of the fuse to be
purchased, depend on the Power Service PSB model.
Refer to the table below for optimal installation.
PSB Model

PSB 12-40

PSB 12-80
PSB 24-30
PSB 24-60
PSB 12/24-20
PSB 12/24-40
PSB 24/12-40
PSB 24/12-80
15.POWER CABLE SECTION
These are power cables:
Connection between the Starter battery positive
terminal and Ref. A of the PSB (fig. 1).
Connection between Leisure battery positive pole
and Ref. B of the PSB (fig. 1).
Connection between the negative poles of the two
batteries and Ref. C of the PSB (fig. 1).
The cross-section to be chosen depends on the
POWERSERVICEPSB
the cables themselves.
Input fuse
(Starter battery positive
pole)
60A - 70A
100A - 125A
60A
80A
60A - 70A
100A - 125A
40A - 50A
60A
model and also on the length of
22
Output fuse
(Leisure battery positive
pole)
50A - 60A
90A - 100A
40A
70A - 80A
25A - 30A
50A - 60A
50A - 60A
90A - 100A

Advertisement