  • Page 1 POWERCHARGERPRO User Manual ITALIANO INGLESE Valido per i seguenti modelli Valid for the following models PFC0150-12CH10S PFC0300-24CH10S PFC0300-12CH15S PFC0600-24CH15S PFC0600-12CH20S PFC0600-24CH20S PFC0600-12CH25S PFC1200-24CH30S PFC1200-36CH25S...
  • Page 2 INSTRUCTIONS FOR THE PROPER DISPOSAL  This electronic product is subject to the European Directive 2012/19 / EU. Comply with local waste disposal regulations, do not dispose of old products with normal household waste. The proper disposal of products that can no longer be used prevents potential negative consequences for the environment and for the population.
  • Page 3: Table Of Contents

    INDICE | INDEX 1. ISTRUZIONI SULLA SICUREZZA 2. CONTENUTO DELLA CONFEZIONE 3. DESCRIZIONE 4. STRUTTURA 5. SELEZIONE CURVA DI CARICA 6. ANALISI CURVE DI CARICA 7. INSTALLAZIONE 8. INDICATORE REMOTO (PIN 2) 9. INDICATORI LED 10. CARATTERISTICHE TECNICHE 11. F.A.Q. 12.
  • Page 4 • Le informazioni contenute in questo manuale sono soggette a modifiche senza preavviso. NDS Energy s.r.l. si riserva il diritto di apportare modifiche e migliorie al prodotto in qualsiasi momento senza...
  • Page 5: Contenuto Della Confezione

    preavviso e senza obbligo di applicare questi cambiamenti ai dispositivi precedentemente distribuiti. • Le immagini dei prodotti sono puramente indicative e potrebbero pertanto non essere perfettamente rappresentative delle caratteristiche del prodotto, differendo per colori, dimensioni o accessori. 2. CONTENUTO DELLA CONFEZIONE Controllare il contenuto della confezione: •...
  • Page 6: Struttura

    4. STRUTTURA POWERCHARGERPRO è dotato di un ingresso per la corrente elettrica 230V, un’uscita 12V o 24V per la batteria o il sistema di ricarica e in alcuni modelli è presente una coppia di cavi che portano il segnale pulito di un relè. N°...
  • Page 7: Selezione Curva Di Carica

    5. SELEZIONE CURVA DI CARICA POWERCHARGERPRO supporta la carica di batterie Piombo/Acido (AGM, Gel, Acido Libero) e Litio (LiFePO a seconda dei modelli. La curva di carica va selezionata in base al tipo di batteria in dotazione e per impostarla è necessario agire sui selettori del Dip Switch posto internamente.
  • Page 8 CONFIGURAZIONI VALIDE PER I MODELLI: PFC0300-12CH15S PFC0600-12CH25S PFC0600-12CH20S CURVA POSIZIONE TECNOLOGIA FASI NUMERO SWITCH BATTERIA IUIa 1 = OFF Desolfatazione ON 2 = OFF off off IUUa Generica (Gel, AGM) 1 = ON Desolfatazione OFF Default 2 = OFF 1 = ON LiFePO Desolfatazione OFF 2 = ON...
  • Page 9: Analisi Curve Di Carica

    6. ANALISI CURVE DI CARICA The charging curves below refer to the configurations on page 8. CURVE 1 e 5 V, I BULK ABSORPTION DESULPHATION =2,465 +/-0,15Vpc =2,60Vpc =max 16% I Tempo CURVE 2 e 6 V, I BULK ABSORPTION FLOATING =2,35~2,45Vpc V=2,3Vpc...
  • Page 10 CURVA 7 V, I BULK ABSORPTION DESULPHATION FLOATING 2,35Vpc =2,6Vpc (Errore/inter- V=2,3Vpc ruzione: 2,8V) Fase I Max 16% I Tempo CURVA 3 V, I BULK ABSORPTION =14,5V Tempo...
  • Page 11: Installazione

    CURVE 4 e 8 BULK ABSORPTION DESULPHATION FLOATING V, I =2,45-2,7V =2,35Vpc ~2,45Vpc V=2,25Vpc Fase I Max 1-3% C20 Tempo 7. INSTALLAZIONE Dopo aver impostato la curva di carica in base alla tipologia di batteria da ricaricare, se necessario, è possibile fissare il dispositivo con delle viti sfruttando le flange laterali.
  • Page 12: Indicatore Remoto (Pin 2)

    8. INDICATORE REMOTO (PIN POWERCHARGERPRO mette a disposizione il contatto pulito di un relè per la segnalazione remota della presenza di corrente elettrica esterna 230V. Questo segnale permette di capire, anche a distanza dal dispositivo, se le batterie sono in carica. Seguire gli schemi seguenti per effettuare il collegamento corretto.
  • Page 13 LAMPADINA AUTOMOTIVE...
  • Page 14: Indicatori Led

    9. INDICATORI LED I tre Led, posti sulla parte superiore (o laterale) del dispositivo, consentono di leggere rapidamente lo stato di carica della batteria collegata. La tabella sottostante spiega la relazione tra colore del led e stato del sistema. SEGNALE SIGNIFICATO Led Rosso Allarme: collegamento con polarità...
  • Page 15: Caratteristiche Tecniche

    10.CARATTERISTICHE TECNICHE PFC0150-12CH10S Tensione nominale di ingresso 220-240Vac ± 10% universale Tensione nominale di uscita Corrente di uscita 10A ± 0,5A Frequenza 50-60Hz Bulk Charge 14,4V (2,4V/Cell) Floating Charge 13,5V-13,9V (2,27V/Cell) Autoripristino al termine Protezione cortocircuito della condizione di cortocircuito Autoripristino al termine Protezione inversione di polarità...
  • Page 16 PFC0600-12CH20S Tensione nominale di ingresso 100-240Vac ± 10% universale Tensione nominale di uscita Corrente di uscita 20A ± 0,5A Frequenza 50-60Hz Bulk Charge 14,4V (2,4V/Cell) Floating Charge 13,5V-13,9V (2,27V/Cell) Autoripristino al termine Protezione cortocircuito della condizione di cortocircuito Autoripristino al termine Protezione inversione di polarità...
  • Page 17 PFC0300-24CH10S Tensione nominale di ingresso 100-240Vac ± 10% universale Tensione nominale di uscita Corrente di uscita 10A ± 0,5A Frequenza 50-60Hz Bulk Charge 28,8V (2,4V/Cell) Floating Charge 27V-27,8V (2,27V/Cell) Autoripristino al termine Protezione cortocircuito della condizione di cortocircuito Autoripristino al termine Protezione inversione di polarità...
  • Page 18 PFC600-24CH20S Tensione nominale di ingresso 100-240Vac ± 10% universale Tensione nominale di uscita Corrente di uscita 20A ± 0,5A Frequenza 50-60Hz Bulk Charge 28,8V (2,4V/Cell) Floating Charge 27V-27,8V (2,27V/Cell) Autoripristino al termine Protezione cortocircuito della condizione di cortocircuito Autoripristino al termine Protezione inversione di polarità...
  • Page 19 PFC1200-36CH25S Tensione nominale di ingresso 100-240Vac ± 10% universale Tensione nominale di uscita Corrente di uscita 25A ± 0,5A Frequenza 50-60Hz Bulk Charge 43,2V (2,4V/Cell) Floating Charge 40,5V-41,7V (2,27V/Cell) Autoripristino al termine Protezione cortocircuito della condizione di cortocircuito Autoripristino al termine Protezione inversione di polarità...
  • Page 20 11. F.A.Q. POWERCHARGERPRO carica batterie Litio LiFePO Sì, per i modelli: P F C 0 3 0 0 - 1 2 C H 1 5 S , P F C 0 6 0 0 - 1 2 C H 2 0 S , PFC0600-12CH25S.
  • Page 21: Garanzia

    12.GARANZIA...
  • Page 23 • The information contained in this manual may be changed without notice. NDS Energy s.r.l. reserves the right to make changes and improvements to the product at any time without notice and without...
  • Page 24: Contents Of The Pack

    obligation to apply these changes to the devices previously distributed. • The images of the products are purely indicative and may therefore not be fully representative of the characteristics of the product, differing in color, size or accessories. 2. CONTENTS OF THE PACK Check the package contents: •...
  • Page 25: Architecture

    4. ARCHITECTURE POWERCHARGERPRO works with a 230V input current and 12V or 24V output, for the battery or charging system, and (in some models) there is a pair of cables carrying potential-free contact of a relay. N° PIN CONNECTION Positive and negative electrical connection for battery to be charged Potential-free contact of a relay for the remote status led connection...
  • Page 26: Charging Curve Selection

    5. CHARGING CURVE SELECTION POWERCHARGERPRO can charge Lead/Acid (AGM, Gel, Wet) and Lithium (LiFePO ) batteries depending on the model. The charging curve must be selected according to the battery type; to set it it is necessary to act on the Dip Switch selectors located internally.
  • Page 27 SETTINGS VALID FOR THE FOLLOWING MODELS: PFC0300-12CH15S PFC0600-12CH25S PFC0600-12CH20S CURVE SWITCH BATTERY PHASE NUMBER SETUP TECHNOLOGY IUIa 1 = OFF Desulphation ON 2 = OFF off off IUUa Generic (Gel, AGM) 1 = ON Desulphation OFF Default 2 = OFF 1 = ON LiFePO Desulphation OFF...
  • Page 28: Charging Curves Analisys

    6. CHARGING CURVES ANALISYS The charging curves below refer to the configurations on page 28. CURVES 1 e 5 BULK ABSORPTION RECONDITIONING V, I =2,465 +/-0,15Vpc =2,60Vpc =max 16% I Time CURVES 2 e 6 V, I BULK ABSORPTION FLOATING =14,5V V=13,7V Time...
  • Page 29 CURVE 7 V, I BULK ABSORPTION RECONDITIONING FLOATING 2,35Vpc =2,6Vpc (Error/inter- V=2,3Vpc rupt:2,8V) phase: Max 16% I Time CURVE 3 V, I BULK ABSORPTION =14,5V Time...
  • Page 30: Installation

    CURVES 4 e 8 V, I BULK ABSORPTION RECONDITIONING FLOATING =2,45-2,7V =2,3Vpc ~2,45Vpc V=2,25- 2,7Vpc phase: Max 1-3% C20 Time 7. INSTALLATION After setting the charging curve according to the battery technology to be recharged, if necessary, the device can be fixed with screws using the side flanges. Then the electrical connections must be made according to the following diagram.
  • Page 31: Remote Status Led Connection (Pin 2)

    8. REMOTE STATUS LED CONNECTION (PIN 2) POWERCHARGERPRO provides a Potential-f ree contact of a relay for a remote status LED connection that shows the external 230V electricity presence. This signal allows to understand, even remotely from the device, if the batteries are charging. Follow the diagrams below to make the correct connection.
  • Page 32 CAR BULB...
  • Page 33: Led Indicators

    9. LED INDICATORS The three LEDs, located on the top (or side), allow to quickly read the charge status of the connected battery. The table below explains the relationship between LED color and system status. SIGNAL MEANING Red LED Alarm: connection with reversed Steady or Flashing polarity or voltage too high Yellow LED...
  • Page 34: Technical Features

    10.TECHNICAL FEATURES PFC0150-12CH10S Input Nominal Voltage 220-240Vac ± 10% universal Output Nominal Voltage Output Current 10A ± 0,5A Frequency 50-60Hz Bulk Charge 14,4V (2,4V/Cell) Floating Charge 13,5V-13,9V (2,27V/Cell) Automatic reset at the end of the Short circuit protection short circuit condition Automatic reset at the end of the Inverse polarity protection inverse polarity condition...
  • Page 35 PFC0600-12CH20S Input Nominal Voltage 100-240Vac ± 10% universal Output Nominal Voltage Output Current 20A ± 0,5A Frequency 50-60Hz Bulk Charge 14,4V (2,4V/Cell) Floating Charge 13,5V-13,9V (2,27V/Cell) Automatic reset at the end of the Short circuit protection short circuit condition Automatic reset at the end of the Inverse polarity protection inverse polarity condition Safe connection,...
  • Page 36 PFC0300-24CH10S Input Nominal Voltage 100-240Vac ± 10% universal Output Nominal Voltage Output Current 10A ± 0,5A Frequency 50-60Hz Bulk Charge 28,8V (2,4V/Cell) Floating Charge 27V-27,8V (2,27V/Cell) Automatic reset at the end of the Short circuit protection short circuit condition Automatic reset at the end of the Inverse polarity protection inverse polarity condition Safe connection,...
  • Page 37 PFC600-24CH20S Input Nominal Voltage 100-240Vac ± 10% universal Output Nominal Voltage Output Current 20A ± 0,5A Frequency 50-60Hz Bulk Charge 28,8V (2,4V/Cell) Floating Charge 27V-27,8V (2,27V/Cell) Automatic reset at the end of the Short circuit protection short circuit condition Automatic reset at the end of the Inverse polarity protection inverse polarity condition Safe connection,...
  • Page 38 PFC1200-36CH25S Input Nominal Voltage 100-240Vac ± 10% universal Output Nominal Voltage Output Current 25A ± 0,5A Frequency 50-60Hz Bulk Charge 43,2V (2,4V/Cell) Floating Charge 40,5V-41,7V (2,27V/Cell) Automatic reset at the end of the Short circuit protection short circuit condition Automatic reset at the end of the Inverse polarity protection inverse polarity condition Safe connection,...
  • Page 39: Warranty

    12.WARRANTY...
  • Page 40 TUTTA L’ENERGIA CHE TI SERVE ALL THE ENERGY YOU NEED 0042_MANS_ PowChPro_IT_GB03 NDS ENERGY s.r.l. Via Pascoli, 96/98 65010 Cappelle sul Tavo (Pe) Italy Tel.:+39 085 4470396 web: www.ndsenergy.it email: customer@ndsenergy.it LIKE US: facebook.com/ndsenergysrl...

Table of Contents