Summary of Contents for SELVAS Healthcare Accuniq BC300
Page 1
User Manual BC300 English. 06/2021. V3.01...
Page 2
The device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC. THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93/42/EEC SELVAS Healthcare, Inc. 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea TEL: 82-42-879-3000, FAX: 82-42-864-4462 Obelis s.a.
User Manual BC300 INTRODUCTION We highly appreciate that you chose our company’s product. You are kindly requested to be familiar with these directions before using this product and always keep it together with the product. In case you are not sure about any directions or problems arising while using the product, please contact our service center.
SELVAS Healthcare, Inc. Note "Notice" indicates important information to notify installation, operation or maintenance of this device. "Notice" is important but not hazard-related. Hazard warnings are not included here. CLASSIFICATION AND COMPLIANCE This device is classified as; Class 1 type-BF against electric shock ...
Page 7
User Manual BC300 Prohibition The unit has previously been adjusted in the factory for optimum performance. Do not attempt to adjust switches or any other things except those specified in this manual for operation. Caution If you have experienced any trouble with the unit, switch it off immediately, and contact our company or its authorized dealer for assistance.
Page 8
SELVAS Healthcare, Inc. Note This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-2:2014. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity.
User Manual BC300 Note Incorrect operation or failure of user to maintain the unit spares the manufacturer or his agent of the responsibility for system’s non-compliance with specifications or responsibility for any damage or injury. This manual is made for informational purpose and this manual and product are not meant to be a substitute for the advice provided by your own physician or other medical problem.
Page 10
SELVAS Healthcare, Inc. SYMBOL INFORMATION General mandatory action sign Caution Waste Electrical and Electronic Equipment (WEEE) The device could be sent back to the manufacturer for recycling or proper disposal after their useful lives. Alternatively the device shall be disposed in accordance with national laws after their useful lives.
RoHS2 Guidance for Electromagnetic compatibility (EMC) Details about the electromagnetic compatibility (EMC) of the ACCUNIQ BC300 are given below. Before using the ACCUNIQ BC300, be sure to read and understand the following information. Guidance and manufacturer’s declaration – electromagnetic emissions The ACCUNIQ BC300 is intended for use in the electromagnetic environment specified IEC 60601-1- 2:2014 (Fourth Edition).
Page 12
SELVAS Healthcare, Inc. The ACCUNIQ BC300 is intended for use in the electromagnetic environment specified IEC 60601-1- 2:2014 (Fourth Edition). _INTRODUCTION...
User Manual BC300 ABOUT BODY COMPOSITION Body Composition Human body consists of body fat and lean body. Lean body means non-fat constituents of human body like body water, muscles, bones, etc. Body water is divided into intra- and extra-cellular water and the ratio between them is controlled and maintained within a certain range.
SELVAS Healthcare, Inc. Abdominal Fatness Body fat is divided into subcutaneous fat and visceral fat. Visceral obesity is considered to be a critical risk factor along with Percent of body fat. Lipoprotein lipase can be easily activated in visceral fat, and it cause visceral fat to be dissolved easily.
User Manual BC300 TERM AND FUNCTION OF EACH PART Main Body Front Part Color LCD Key Pad Handle Electrode Thermal printer (option) Color LCD screen : It displays the procedure and results. Handle Electrode : Handle Electrode measure the impedance by sending harmless electric current to ...
SELVAS Healthcare, Inc. Rear Part ZIGBEE port Blood Pressure Power switch monitor port Adapter port Printer port Computer port Blood pressure monitor (RS-232C) port: Connecting blood pressure monitor (OPTION) by SELVAS Healthcare, Inc. Printer (USB(A)) port: Connecting the printer offered with this device.
User Manual BC300 It is impossible to use both ZIGBEE (Wireless communication) and height meter. When height meter is connected, you can not use wireless communication. Base Part Locking handle Weight scale Plate electrode Locking handle: When transport is necessary, the column can be folded down by turning the screw ...
SELVAS Healthcare, Inc. Bottom of the head part Start button Start button: Start button after input of personal data. Note Head part is connected to main body by limited-length curl cord. It allows measuring people in 100 – 200 cm height.
User Manual BC300 Key Pad button: When you press this button at initial screen, you can search ID and check the recent results of searched ID. Print the result with PRINT button. button: You can select gender; male or female. ...
SELVAS Healthcare, Inc. Basic Package Basic package of this product is composed of ① Main body ② User guide ③ Body composition management program (CD) ④ A4 Result Sheet ⑤ USB cable ⑥ Power cable and adapter ① Main body ②...
User Manual BC300 Options Automatic Blood Pressure Monitor If SELVAS's automatic blood pressure monitor for hospital is connected to this device, the measurer can easily check his/her blood pressure. Especially the patient with the hypertension can manage his/her blood pressure efficiently through body weight control.
Page 22
SELVAS Healthcare, Inc. Height Meter This is an instrument to measure subject’s height more accurately and quickly. It employs standoff determination method using ultrasonic sensor. Refer to INSTALLATION MANUAL. Caution Optional devices are should be use only from our company.
User Manual BC300 INSTALLATION Installation of product Unscrew all screws from the carry bag with screwdriver (attached on the top of the bag). "TOP" mark should be indicated on top of the box when you place the carry bag. Unlock the both handles to open the bag.
Page 24
SELVAS Healthcare, Inc. Put your hands as shown in the picture. Hold the device with both hands and take the device out. Place the device on the flat floor. Stand the body part of device with one hand and fix the locking handle by turning it clockwise with another hand.
User Manual BC300 Power Supply Connect the adapter to the adapter jack placed on the rear panel of this device. After the cables are connected to each jack, turn on the power switch placed beside the adapter jack. Caution Before connecting a peripheral device to this device, the power should be turned off. Otherwise this device can malfunction or be damaged due to electric shock.
SELVAS Healthcare, Inc. Peripheral Device Installation Connecting Computer Connect the “USB(B)” port placed on the rear panel of this device to the USB port in computer with USB cable. Connecting Printer Connecting the device and the printer directly Connect A4 printer offered with this device to the “USB(A)” port placed on the rear panel of this device with USB cable.
User Manual BC300 Connecting the device, computer, and the printer Connect a computer to the “USB(B)” jack placed on the rear panel of the device with USB cables. Connect the printer to the computer with printer cable. The result sheet can be printed out from the printer.
SELVAS Healthcare, Inc. Replacing of thermal paper (Option) Replace thermal paper while the power is on. Turn the screws counterclockwise and open the cover as shown in the picture. Insert the thermal paper to the direction as shown in the picture.
Page 29
User Manual BC300 [FEED/CUT functions of thermal printer] FEED Function CUT Function Press ‘ ’ button 5 times at initial screen. Press ‘ ’ button 5 times at initial screen. Press‘ ’ button to print the Press‘ ’ button to cut the thermal paper.
SELVAS Healthcare, Inc. SYSTEM SETUP SYSTEM SETUP allows users to change the setting of operational parameters. Note The contents in SYSTEM SETUP can be changed for improvement. Entering SYSTEM SETUP At the initial screen, press '◀ → 1 → 2 → 3 → 4 → ▶' button in key pad to enter 'SYSTEM SETUP' screen.
User Manual BC300 Abdominal Circumference GUIDE CHILD/ADULT/AUTO HEIGHT METER Selecting a Menu in SYSTEM SETUP Select the menu by pressing ‘◀’ and ‘▶’ button. Press BACK button in key pad. (BACK button act as ‘SET’ button in SYSTEM SETUP and NEXT button act as ‘CLOSE’...
SELVAS Healthcare, Inc. Setup DATE/TIME It is to set date and time (year, month, day, hour, and minute). Select (DATE / TIME) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK button in key pad. Pre-set: The date of the device released from the manufacturer's factory.
User Manual BC300 VOLUME It adjusts the volume of voice guidance. Select (VOLUME) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK button in key pad. Pre-set: 3 Range: 0 ~ 9 Adjust volume with‘◀’ and ‘▶’ button in key pad. ...
SELVAS Healthcare, Inc. Return to SYSTEM SETUP screen by pressing NEXT button in key pad. PRINT POSITION It adjusts the printing position in the direction of U-D (up-down) and L-R (left-right) to fit to the pre- formatted result sheet.
User Manual BC300 Print test When you press “Print” button, you can print the test page of BCA or CHD. CLOTHES It is to subtract the weight of clothes worn by the subjects from measured weight. Calculated value from this setting is used in body composition analysis as subject’s weight. Select (CLOTHES) on SYSTEM SETUP screen with ‘◀’...
SELVAS Healthcare, Inc. Select (abdominal fatness) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK button in key pad. Pre-set: NO Choose YES or NO with ‘◀’ and ‘▶’ button in key pad. If YES is chosen, abdominal analysis is performed to all age.
Return to SYSTEM SETUP screen by pressing NEXT button in key pad. Communication Select the connecting method between ACCUNIQ BC300 and a computer. 'CABLE' is for USB cable and 'WIRELESS' is for wireless communication. Select (COMMUNICATION) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK ...
SELVAS Healthcare, Inc. Return to SYSTEM SETUP screen by pressing NEXT button in key pad. ID usage It is set to whether to use ID or not. Select (ID usage) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK button in ...
User Manual BC300 Note When FLASH MEMORY is used, The result can be saved up to 1000. If the number of saved results exceeds 1000, the new result will be overwritten from the oldest result. The results can be deleted and initialized.
SELVAS Healthcare, Inc. GUIDE This is to display guide screen. Select (Guide) on SYSTEM SETUP screen with ‘◀’ and ‘▶’ button and press BACK button in key pad. Preset: YES Choose YES or NO with ‘◀’ and ‘▶’ button in key pad.
User Manual BC300 Press BACK button in key pad to save it. Return to SYSTEM SETUP screen by pressing NEXT button in key pad. Note The print format of result sheet CHILD: No matter what age is set, it prints the result sheet for CHILD. ...
Page 42
SELVAS Healthcare, Inc. If height meter is not connected, “Height meter is not connected, move to height input mode’ message will be appeared. Check the cable which connects the height meter to the device. If message above appears while height meter is connected, please ask us or appointed agent.
User Manual BC300 MEASUREMENT AND ANALYSIS Precautions for Measurement The reliability of the results can be assessed by its accuracy. The "Accuracy" of the device is determined by comparing the actual body composition and the results from Body Composition Analyzer. The "Reproducibility"...
SELVAS Healthcare, Inc. etc.) are kept same, the reproducibility of a device is obtained. Therefore, the data can be used to evaluate the change of body composition. Correct Posture How to Touch Plate Electrodes Make sure plate electrodes are clean.
User Manual BC300 Note When a subject has small hands or feet and cannot cover all electrodes sufficiently, please pay attention to touch all electrodes fairly. How to touch electrodes will affect the reliability of analyzed value. During measurement the subject should not be touched by other person or conductive materials.
SELVAS Healthcare, Inc. Blood pressure analysis: Blood pressure monitor can be connected to the device. Analysis using software program: Body composition management software or professional counseling manager program can be installed in a computer which is connected to the device.
Page 47
User Manual BC300 Personal information Input personal information in the order of ID, height, age, and gender. Confirm the information and press NEXT button. (If ID usage is selected from ’SYSTEM SETUP’, ID screen will be pop-up.) [ID usage: YES] ID input ...
Page 48
SELVAS Healthcare, Inc. Gender selection “Select your gender.” appears. Select MALE or FEMALE with Gender button in key pad. After finishing the subject’s personal data input, press NEXT button in key pad. [ID usage: NO] Input height ...
Page 49
User Manual BC300 [Measure height] If height meter is selected as an option, height meter measurement screen will appear after measuring weight. Press NEXT button in key pad. Measurement posture 1 After inputting the subject’s personal data, the screen changes as shown in the picture.
SELVAS Healthcare, Inc. Note Press both start buttons for 2 seconds. Do not move or bend the arms until the measurement is completed. Measuring time is within 1 minute. When the measurement is wrong, Error message appears on the screen.
Analysis Using Blood Pressure Monitor/Software Program The blood pressure monitor from SELVAS Healthcare, Inc. can be connected to the device as an option. In this way, the blood pressure can be monitored together with weight control. It helps to manage the body fat while checking the blood pressure simultaneously.
Page 52
SELVAS Healthcare, Inc. The results of blood pressure and body composition are immediately displayed on the computer screen after the completion of body composition analysis. Save the data or print it out. Note Blood pressure should be measured before body composition analysis. Refer to the user manual of blood pressure monitor for more detail.
User Manual BC300 STORAGE OF DATA USING USB MEMORY Storage of data Select of FLASH MEMORY Insert USB memory stick into USB(A) jack placed on the back side of the device. The following message appears. ‘Do you want to write data to USB memory stick?’on initial screen. Press ‘YES’ to send to USB memory. Transmitting message will be displayed on the screen.
Please insert USB MEMORY and measure again. If the message above appears even USB memory stick is inserted, take out the USB MEMORY and insert it again. Please use the USB MEMORY which provided by SELVAS Healthcare, Inc. Note The data can be saved only when ‘ID USAGE’ function is activated in SYSTEM SETUP.
User Manual BC300 Data Backup (Only with FLASH MEMORY) When error occurred while using FLASH MEMORY, error message appears as shown in the picture. In this case, please turn off and on the power and insert USB on initial screen. Press ‘◀→7777→▶’...
SELVAS Healthcare, Inc. RESULT INTERPRETATION Here's the explanation and the criteria of the printed results. Personal Data The subject's name / ID, date, height, weight, age and gender are indicated on the result sheet. Logo The user can input LOGO such as name of hospital, sports center, or obesity clinic, telephone number, address, contact person, etc.
Page 57
User Manual BC300 Percent Body Fat (P.B.F., %): It is the ratio (%) of the body fat based on the subject’s weight. low-fat normal over-fat obese severe obese Male less than 15 15 ~ ≤ 20 20 ~ ≤ 25 25 ~ ≤...
Page 58
SELVAS Healthcare, Inc. Level 16~20 corresponds to visceral fat typeⅡ. V.F.A. (Visceral Fat Area): normal range is 50 ~ 100 cm (male), 40 ~ 80 cm (female). Abdominal circumference: Normal range is <102cm (male), <88cm (female). Abdominal Circumference is an estimated value in case of measure the navel circumference.
Page 59
Blood Pressure (13) When the blood pressure monitor supplied from SELVAS Healthcare, Inc. is connected to the device, blood pressure can be measured and the result can be printed out. Systolic blood pressure, diastolic blood pressure, and pulse are printed on result sheet. It helps to recognize hypertension assessment related to obesity.
SELVAS Healthcare, Inc. STORAGE & MAINTENANCE Pay attention to the allowable value to electric current. Avoid direct sunlight, humidity, dust, thick oil and salty or extreme changes in temperature. Do not install or store the device in a place where any chemicals or gas is stored.
Page 61
User Manual BC300 Disinfection: After measurement, use a soft gauze cloth with volatile liquid like benzene and alcohol. Then, wipe the enclosure with a soft lint. Please wipe after every measurement for electrode disinfection. Refer to “SAFETY PRECAUTIONS.” Caution Users must wipe with safety equipments such as gloves in disinfecting electrode. Our company does not take a responsiblity for safety accident caused by user's carelessness.
SELVAS Healthcare, Inc. ERROR & REPAIR Kinds of Error & Repair Error Cause Repair Clean the measuring parts (the electrodes, palms, and soles) and try again. When the subject’s body impedance Measure again with correct posture. is deviated from the limit Out of range of Do not move during measurement.
User Manual BC300 Moving during measurement Error & Repair Error Cause Repair Measure in unstable condition such as right after the exercise, bath, Measure again in a stable condition sweat, or drinking lots of water. with the correct posture. Moving or speaking during the Do not move or speak during the ...
SELVAS Healthcare, Inc. AFTER SERVICE AFTER SERVICE If there is any problem with the unit, please follow the steps below; Contact our company’s Overseas Service Department immediately. After gathering the model name, Serial Number, date of purchase and description of the problem, contact our company with information shown below.
Page 65
User Manual BC300 Turn off the power of the peripheral devices and disconnect all cables. Disassemble the device in reverse order of assembly. Pack the device with the original packing materials. Transport it carefully. AFTER SERVICE_...
SELVAS Healthcare, Inc. SPECIFICATION DIVISION SPECIFICATION Model ACCUNIQ BC300 Measuring BIA via tetra-polar electrode method using 8 touch electrodes. method Frequency Range 5, 50, 250 kHz Measuring site Whole body and Segmental measurement (arms, legs, and trunk) Main items [Result for Body Composition Analysis]...
Page 67
User Manual BC300 DIVISION SPECIFICATION Weight About 10kg (main unit) Measuring time Within 1 minute Input height 50 ~ 220 cm Measuring weight 10 ~ 200 kg Applicable age 1 ~ 99 years old Operation Ambient temperature range +5 to +40 °C ambient Relative humidity range 15 to 93 % (non condensing) Storage ambient...
Page 68
SELVAS Healthcare, Inc. WARRANTY Name of product Body Composition Analyzer Name of model ACCUNIQ BC300 Serial number Period of warranty Within 1 year from the date of manufacture Date of purchase Customer Add. Name Tel. Dealer (market) Add. Name Tel.
Page 69
Pass/Fail Measurement Proper measurement Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC300 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
Page 70
SELVAS Healthcare, Inc. Daily Check List Management No. Item Inspection Subject Requirements Judgment Remarks Visual Check scratch, crack, Enclosure Pass/Fail deformation and rust Labels and panels No peeling and dust Pass/Fail Mainframe No damage Pass/Fail Electrode No scratch and damage...
Page 72
SELVAS Healthcare, Inc. HEADQUARTERS 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea Tel 82-42-879-3000 Fax 82-42-864-4462 EUROPEAN REPRESENTATIVE VITAKO Sp.z.o.o ul. Stanislawa Żaryna 7c 02-593 Warszawa, POLAND Tel +48 505 522 888 If the problems continue, call the service center. When you ask for service, the manufacturer’s label, serial number, date of original purchase and explanation of malfunction will be required.
Need help?
Do you have a question about the Accuniq BC300 and is the answer not in the manual?
Questions and answers