Summary of Contents for SELVAS Healthcare ACCUNIQ BC720
Page 1
User Manual BC720 English. 06/2021. V3.02...
Page 2
The device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC. THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93/42/EEC SELVAS Healthcare, Inc. 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea TEL: +82 42 879 3000, FAX: +82 42 864 4462 Obelis s.a.
CONTENTS Connecting Printer ............26 Connecting Blood Pressure Monitor ....26 CONTENTS Ultrasonic Height meter SM103 ......27 INTRODUCTION SYSTEM SETUP INTENDED USE ................5 Entering SYSTEM SETUP ............. 28 WORD DEFINITIONS ............... 5 Menu in SYSTEM SETUP ..........28 CLASSIFICATION AND COMPLIANCE ......
Page 4
SELVAS Healthcare, Inc. Kinds of Error & Repair ............51 Error occurrence & Repair ..........52 AFTER SERVICE AFTER SERVICE ................ 54 How to contact SELVAS Healthcare ..... 54 PACKING AND TRANSPORT ..........54 SPECIFICATION WARRANTY _CONTENTS...
You are kindly requested to be familiar with these directions before using this product and always keep it together with the product. In case you are not sure about any directions or problems arising while using the product, please contact with SELVAS Healthcare or its local distributor where is purchased. We will provide you with detailed instructions.
SELVAS Healthcare, Inc. Note “Notice” indicates important information in order to notify installation, operation or maintenance of this device. "Notice" is important but not hazard-related. Hazard warnings are not included here. CLASSIFICATION AND COMPLIANCE This device is classified as; Class 1 type-BF against electric shock ...
Page 7
Caution If you plan to connect any device from other manufacturers electrically or mechanically to the unit, contact SELVAS Healthcare or its authorized dealer for instructions before doing so. When you connect computer or other system to the unit (RS-232C), the attached systems should be those certified by IEC 950 or equivalent standards for data processing equipment.
Page 8
SELVAS Healthcare, Inc. Where the angle of inclination of mounting surface exceeds 10 degrees. Where the unit is exposed to direct sunlight. Caution This device needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
Page 9
User Manual BC720 Prohibition Never jump on the Weighing Platform, there may be a risk of stumbling and malfunction of the equipment. Note This equipment has been tested and found to comply with the limits for medical devices according to IEC 60601-1-2:2014. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.
Defective units or accessories must be packed in the replacement cartons to be shipped off from you to SELVAS Healthcare. Shipping and insurance costs for return of defective unit must be prepaid by the users. Warning Do not modify this equipment without authorization of the manufacturer.
Page 11
User Manual BC720 SYMBOL INFORMATION Degree of protection against electric shock: TYPE BF Please observe operating instructions General warning sign General prohibition sign General mandatory action sign Caution Waste Electrical and Electronic Equipment (WEEE) The device could be sent back to the manufacturer for recycling or proper disposal after their useful lives.
Medical Device Guidance for Electromagnetic compatibility (EMC) Details about the electromagnetic compatibility (EMC) of the ACCUNIQ BC720 are given below. Before using the ACCUNIQ BC720, be sure to read and understand the following information. Guidance and manufacturer’s declaration – electromagnetic emissions The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1- 2:2014 (Fourth Edition).
Page 13
User Manual BC720 Recommended separation distances between portable and mobile RF communications equipment and the ACCUNIQ BC720 The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1- 2:2014 (Fourth Edition). INTRODUCTION_...
SELVAS Healthcare, Inc. ABOUT BODY COMPOSITION Body Composition Human body consists of body fat and lean body. Lean body means non-fat constituents of human body like body water, muscles, mineral, etc. Body water is divided into intra- and extra-cellular water and the ratio between them is controlled and maintained within a certain range.
Page 15
User Manual BC720 Abdominal Fatness Body fat is divided into subcutaneous fat and visceral fat. Visceral obesity is considered to be a critical risk factor along with Percentage of body fat. Lipoprotein lipase can be easily activated in visceral fat, and it causes visceral fat to be dissolved easily. Dissolved visceral fat goes into liver through the blood vessel and causes fatty liver or increases lipid in the blood.
SELVAS Healthcare TERMS OF EACH PART AND FUNCTION Main Parts The main system of ACCUNIQ BC720 consists of as follows. ① Main body ② User manual & Data ③ Adapter ④ USB Cable management program ⑤ Wi-Fi Dongle ⑥ Bolts ⑦...
Page 17
User Manual BC720 Data management program This program helps managing body composition easily and systematically. It shows the core items needed to control body composition. The items include measured body composition, dietary control plan, exercise plan, etc. ㅍ If the device is connected to blood pressure monitor, it also indicates the measurer's blood pressure.
SELVAS Healthcare Ultrasonic Height Meter SM103 It is an instrument to measure users' Height more accurately and quickly. It employs standoff determination method using ultrasonic sensor. It combines the technology of artificial intelligence and reflected characteristics of ultrasonic height meter.
User Manual BC720 Appearance of the device Front Part The front and back of ACCUNIQ BC720 looks as below. [Front Part] [Rear Part] Display / Operation Part Body Part Base Part TERMS OF EACH PART AND FUNCTION_...
It also shows measuring process in messages and graphic display. Key pad There is a keypad in ACCUNIQ BC720. The function of each button is same as the touch screen. Touch panel LCD (Liquid Crystal Display) panel as touch screen It is easy to input data.
User Manual BC720 Body Part Holders of Handle electrode Handle electrodes (Applied part) Cable Holders of Handle electrode Handle electrodes are rested on the holder when they are not used. Handle electrodes (Applied part) It measures the resistance of body. Hold them with both hands during measurement.
SELVAS Healthcare Base Part Body cover Horizontal level Scale Plate electrodes (Applied part) 4 Wheels Scale: Measure weight. Plate electrodes (Applied part): The user should step them in bare feet. Horizontal level: A level to regulate horizontality of the analyzer.
Printer: A port to connect printer. Computer: A port to connect computer with USB Cable. Blood Pressure: A port to connect blood pressure monitor manufactured by SELVAS Healthcare, Inc. Adapter: Connecting the adapter. Height: A port to connect ultrasonic height meter.
SELVAS Healthcare INSTALLATION Power Supply Connect the power cable to the 'ADAPTER' placed on the lower back panel of the device. Connect the cable. Turn on the power switch placed next to Power input, then after moment initial screen animation is displayed automatically.
User Manual BC720 Peripheral Device Installation Connecting Computer Connect the “COMPUTER” port placed on the rear panel of this device to the computer with USB cable. Or it can be connected through Bluetooth. Note If use USB port, the cable should be connected to the computer port. When use computer port, USB driver should be installed at first.
SELVAS Healthcare Connecting Printer Connect A4 Printer to the ' ' port placed on the back with USB cable. There are two ways to connect printer. Unit-Printer interface directly. Unit-Computer-Printer connecting. Connecting Blood Pressure Monitor Connect blood pressure monitor to 'BLOOD PRESSURE' port placed on the rear panel of the main unit...
For assembly, push the lower board of the ultrasonic height meter into the bottom back of ACCUNIQ BC720. Fix the left and right parts firmly using hinge and screw. Connect RS-232 cable to the 'HEIGHT ' port placed on the rear panel of ACCUNIQ BC720. INSTALLATION_...
SELVAS Healthcare SYSTEM SETUP ‘SYSTEM SETUP' allows the users to change the setting of operational parameters. Note For the purpose of improvement, the contents in SYSTEM SETUP can be changed. Entering SYSTEM SETUP On the initial screen, press the “...
User Manual BC720 Automatic print settings and Number of auto prints Print Position Result sheet setting Logo Result Sheet BCA / SEG/CHD. result sheet setting Abdominal analysis result setting WiFi connection Communication Bluetooth Weight Measurement or Input Weight/Height Weight Calibration Height Calibration Optional equipment (Height meter / blood pressure Option Management...
SELVAS Healthcare Date Type: Use the <, > buttons to select the desired date format: YYYY-MM-DD, MM-DD-YYYY or DD-MM-YYYY. Unit change: Select the units for weight and height in kg / cm or lb / ft. Language: Set the language of menus and prompts.
User Manual BC720 Copy data to Excel file: Export all or part of saved data to an Excel file. Data Backup/Restore: export data to a USB drive, or load data from a USB drive into the device. Printer Printer connection: Connect a printer.
SELVAS Healthcare Communication WiFi connection Bluetooth Weight/Height Weight Measurement or Input: You can measure or input your weight. Weight Calibration: Calibrate the weight value. Height Calibration: Calibrate the height value. _SYSTEM SETUP...
User Manual BC720 Option Management Measurement electrode (foot electrode / ankle electrode): You can select which electrode to use. Optional equipment (Height meter / blood pressure monitor): You can select whether to use these optional devices. Display Touch Calibration: Calibrate the touch position of the touch screen. ...
Page 34
SELVAS Healthcare Problem solving: See the cause of common problems and how to fix them. Remote check: The product can be remotely inspected by a SELVAS technician if a problem occurs. Information: Check the software version of the device.
User Manual BC720 MEASURING AND ANALYZING Precaution for measurement The reliability of the results can be assessed by its accuracy. The "Accuracy" of the device is determined by comparing the actual body composition and the results from Body Composition Analyzer. The "Reproducibility"...
SELVAS Healthcare In order to keep one's health and the balance of body composition, check the changes of body composition through continuous analysis and compare the results. Make sure that the body composition should are measured under the same physical and environmental conditions. If the condition before the measurement such as volume of a meal, meal time, and activities (exercise, sauna, drinking lots of beverage, urination, etc.) are kept same, the reproducibility of a device is obtained.
User Manual BC720 Note If 8 electrodes are not perfectly touched during the measurement, the result is not reliable or the device quits the measurement. Note When the subject has hands or feet that are too small to cover all electrodes sufficiently for measurement, please pay attention to touch all electrodes fairly.
SELVAS Healthcare Do not bend the arm Do not move. Don’t move and the arms Open arms about 30 degrees Keep touching Open about 30 degrees all electrodes (O) Correct posture (X) Incorrect posture Measurement Basic analysis Measurement If you want to start measurement, step on the scale of the product.
Page 39
User Manual BC720 When the weight measurement is complete, the measurement result is displayed. Select member measurement or non-member measurement. Personal data input Input the following information in a order; ID, height, age and gender. Input ID (member measurement) Input your ID.
Page 40
SELVAS Healthcare Measurement posture 1 After inputting the subject’s personal data, the screen changes as shown in the picture. Place your feet precisely on the plate electrodes. Measurement posture 2 Grip the electrode handles correctly. Measurement posture 3 Stretch both arms and spread them 30° from the body.
Page 41
User Manual BC720 If the measurement fails three times in a row, the following message appears. "The measurement can not complete due to the continuous errors. Step down from the scale for the initialization. Refer to the ERROR & REPAIR section for additional detail. ...
SELVAS Healthcare Using Ultrasonic Height Meter An Ultrasonic Height Meter is an optional part. When height meter is connected to ACCUNIQ BC720, it measures the user’s height in accurate way. [Measuring procedure] Connect ACCUNIQ BC720 to ultrasonic Height Meter. Turn on the device and height meter. After the voice guidance, “To start measuring weight”, step on the...
User Manual BC720 Procedure using Blood Pressure Monitor When ACCUNIQ BC720 is connected to Blood Pressure Monitor. Both blood pressure and body composition can be measured. Blood Pressure Monitor should be selected from one of the models from SELVAS Healthcare, Inc.
SELVAS Healthcare RESULT INTERPRETATION ACCUNIQ BC720 indicates the synthetic analysis including edema assessment, prediction of abdominal fatness, segmental analysis, etc. Explanation of each item is as follows. Personal Data The subject's ID / name, date, height, weight, age and gender are indicated on the result sheet.
Page 45
User Manual BC720 Subcutaneous Fat: It exists under our skin and when pulsing with visceral fat, it becomes the total mass of body fat. S.L.M. (Soft Lean Mass): It consists of total body water and protein and some internal organs such as heart, stomach and bowels etc.
Page 46
SELVAS Healthcare Body Mass Index (kg/m ): for Adults EAST ASIA thin normal overweight obese < 18.5 18.5 ~ < 23 23 ~ < 25 over 25 EU and etc. thin normal overweight obese < 18.5 18.5 ~ < 25 25 ~ <...
Page 47
User Manual BC720 Prediction of Abdominal Fat It is the graph of V.F.A. If the user doesn’t exercise and just keep the current life style, the graph indicates how V.F.A increases and how BMR decreases every 5 years. This graph gives motivation to manage daily life style. Segmental Analysis Soft lean mass and edema index of five body parts (left and right arms, left and right legs, and trunk) are analyzed.
Page 48
Blood Pressure (16) When the blood pressure monitor supplied from SELVAS Healthcare, Inc. is connected to the device, blood pressure can be measured and the result can be printed out. Systolic blood pressure, diastolic blood pressure, and pulse are printed on result sheet. It helps to recognize hypertension assessment related to obesity.
If foreign substances are introduced, or if the device is exposed to harmful environments, the unit must be examined by a qualified technician before use. Use only the power cable, adapter, and fuses provided by SELVAS Healthcare. Please confirm the covering of the cable, the state of the adapter connection, and other safety checks...
Page 50
Please refer to and abide by the “SAFETY PRECAUTIONS.” Caution Users must be sure to use sterile safety equipment such as gloves when in contact with or cleaning electrodes. SELVAS Healthcare is not responsible for safety accidents caused by users’ carelessness. _STORAGE & MAINTENANCE...
If the same error is repeated, please contact Impedance is out of range SELVAS Healthcare or its local distributor from Range: 100 ~ 950 Ω where this device is purchased Out of range When the subject’s P.B.F.
There is an error in measured Check installation condition (AC cord or impedance by external around equipment influence. Contact SELVAS Healthcare or distributor 38004 Out of measurement range of Try again after cleaning the hands and ...
Page 53
It can’t measure if the PBF is out of range 38006 Continuous error for 3 times Step off and try again Contact SELVAS Healthcare or distributor 38007 Disconnect Color board and Contact SELVAS Healthcare or distributor Main board...
(You can also contact the following representative or your local distributor) PACKING AND TRANSPORT SELVAS Healthcare wraps this device up with the most suitable method to protect it from any impact or damage during shipping and transporting. This device can be damaged during delivery if it is packed in other ways except the one SELVAS Healthcare uses.
Page 55
User Manual BC720 Turn off the power of the peripheral devices and disconnect all cables. Disassemble the device in reverse order of assembly. Pack the device with the original packing materials. Transport it carefully. AFTER SERVICE_...
L/R, Lower body L/R), Control guide (Target weight, Weight control, Muscle control, Fat control), Impedance (Segmental&Frequency), Blood pressure (when connected with blood pressure monitor of SELVAS Healthcare), QR code [Result for Segmental] Segmental lean mass and assessment, Segmental fat mass and assessment,...
Page 57
User Manual BC720 DIVISION SPECIFICATION Output-DC 12V, 5A, 60W ADAPTER Display 8.4inch wide color LCD Input device Key pad, Touch screen, PC remote control Transmission USB port, RS-232C, Wi-Fi, Bluetooth (Option) device Printing device USB port Dimension 496 x 820 x 1150mm (W x D x H) Weight About 42kg (main unit) Measuring range...
Page 58
SELVAS Healthcare WARRANTY Name of product Body composition analyzer Name of model ACCUNIQ BC720 Serial number Period of warranty / Within 1 year from the date of manufacture Date of purchase Customer Add. Name Tel. Dealer (market) Add. Name Tel.
Page 59
Pass/Fail Measurement Proper measurement Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC720 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
Page 60
Pass/Fail Other Clock Present date/time Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC720 Serial No. Installation place Date of purchase Check date Checked by Approved by Copy this sheet for use If repair is required, write down so in the Remarks column.
Page 62
SELVAS Healthcare, Inc. HEADQUARTERS 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea Tel +82 42 879 3000 Fax +82 42 864 4462 If the problems continue, call the service center. When you ask for service, the manufacturer’s label, serial number, date of original purchase and explanation of malfunction will be required.
Need help?
Do you have a question about the ACCUNIQ BC720 and is the answer not in the manual?
Questions and answers