  • Page 1 User Manual...
  • Page 2: Table Of Contents

    Customer Support ...........35 Intended patient population ........4 MEASUREMENT AND ANALYSIS Word Definitons ............5 SELVAS Healthcare, Inc. Classification and Compliance ......... 5 Precautions for Measurement ....... 36 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea Safety Symbols and Information ......6 Correct Measuring Posture ........
  • Page 3: Introduction

    The following conventions are used throughout the manual to denote information of special emphasis. together with the device. In case you are not sure about any directions or problems arising while using the device, please contact with SELVAS Healthcare or its local distributor where is purchased. We will provide Warning you with detailed instructions.
  • Page 4: Safety Symbols And Information

    SELVAS Healthcare User Manual BC720 SAFETY SYMBOLS AND INFORMATION SYMBOL INFORMATION The International Electro-technical Commission (IEC) has established a set of symbols for medical electrical Manufacturer equipment which classify a connection or warning of any potential hazard. The classifications and symbols are shown below. Save these instructions for your safety.
  • Page 5: Safety Precautions

    SELVAS Healthcare User Manual BC720 SAFETY PRECAUTIONS Caution This device is designed and manufactured with consideration of the safety of the operator and subject and Avoid the following environments for storage; also the reliability of the unit. ・ Where the ambient temperature falls below -25℃ or exceeds 70℃.
  • Page 6 SELVAS Healthcare User Manual BC720 Prohibition Note The unit has previously been adjusted in the factory for optimum performance. Do not In case of patients who have certain diseases, the estimates might be different attempt to adjust switches or any other things except those specified in this manual for operation.
  • Page 7: Guidance For Electromagnetic Compatibility (Emc)

    Details about the electromagnetic compatibility (EMC) of the ACCUNIQ BC720 are given below. Before using the ACCUNIQ BC720, be sure to read and understand the following information. What is obesity? Several methods are used to diagnose obesity, the key to determining the degree of obesity is the amount of 1) Guidance and manufacturer’s declaration - electromagnetic emissions...
  • Page 8: Safety Management

    SELVAS Healthcare User Manual BC720 Body type SAFETY MANAGEMENT About 20 types of body shapes can be derived from body weight, skeletal muscle mass, and body fat mass, and it determines the body shape closest to the user. This device is manufactured according to international standards, and user safety and device reliability can Biological age be guaranteed only when the following precautions are observed.
  • Page 9: Name And Function Of Each Part

    SELVAS Healthcare User Manual BC720 11) Be sure to get inspection service before using the device that has foreign substances or has been NAME AND FUNCTION OF EACH PART exposed to a special environment. 12) When reusing a device that has not been used for a long time, check whether there is no abnormality in Main Components the appearance or function of the device before using it.
  • Page 10: Options

    SELVAS Healthcare User Manual BC720 Options 4. Ultrasonic Height Meter SM103 It is a device that automatically and quickly measures the height 1. Data Management Program more accurately by using the distance measurement method of artificial intelligence and ultrasonic sensor.
  • Page 11: Device Appearance

    SELVAS Healthcare User Manual BC720 Device appearance Body Part [Front part] [Rear part] Display ・ Operation Part Hand electrode hook Body Part Hand electrode Electrode cable ・ Hand electrode hook A hook for hanging an electrode handle Base Part ・ Hand electrode It is the part where the current input for measuring the user's resistance, the measuring device and the user's hand come into contact.
  • Page 12: Rear Part

    A terminal that connects a printer and a device to output the body composition analysis result. ・ Computer port:A terminal for connecting a computer using a USB cable. ・ Blood Pressure Monitor:A port to connect Blood Pressure Monitor manufactured by SELVAS Healthcare, Inc. Caution ・ Adapter port:A terminal for connecting the adapter.
  • Page 13: External Connection

    SELVAS Healthcare User Manual BC720 External connection Caution 1. The PC that connects to the device must comply with IEC60950-1. Caution 2. The PC must be kept up to date latest operating system for cybersecurity. 1. Connect only items that have been specified as part of the device or that have been Therefore, make sure all the latest updates and security patches.
  • Page 14: Blood Pressure Monitor Connection

    SELVAS Healthcare User Manual BC720 Blood Pressure Monitor connection Ultrasonic Height Meter connection This device can be connected to the autonomous Blood Pressure Monitor as an option. Connect the Height Meter connecting jack on the rear bottom part of this device and the Height Meter PC Connect the Blood Pressure Monitor (RS-232C) terminal on the rear part of this device and the Blood port with RS-232C cable provided.
  • Page 15: System Setup

    SELVAS Healthcare User Manual BC720 SYSTEM SETUP Menu Setup item Basic settings Date / Time ‘User Setup’ is built-in to control the operating environment of the device, so the user can set the device Date format environment. Select measurement unit...
  • Page 16: Setup

    SELVAS Healthcare User Manual BC720 Setup Data Management Basic settings ・ Check data / print / delete data: You can confirm, print, or delete data saved in the device. ・ Copy data to Excel file: All or part of the saved data is saved as an Excel file.
  • Page 17: Results

    SELVAS Healthcare User Manual BC720 Results [Internet Settings] 1) Connecting to the Internet via WiFi ・ Select [Connect to WiFi] from Communication > WiFi Connection. ・ When the available networks are displayed, select the network you want to use and then select the [WiFi Connection] button.
  • Page 18: Management Options

    SELVAS Healthcare User Manual BC720 Management options Customer Support ・ Use optional equipment: Select a connected optional device such as a Height Meter or Blood Pressure Monitor ・ Problem solving: You can check the cause of the problem and how to solve it.
  • Page 19: Measurement And Analysis

    SELVAS Healthcare User Manual BC720 ・ Stand so that your feet contact the foot electrode below. MEASUREMENT AND ANALYSIS In this case, be careful not to get your pants or clothes caught between the electrodes and your feet. Precautions for measurement The reliability of the results obtained by analyzing body composition can be judged based on the accuracy.
  • Page 20: Measurement

    SELVAS Healthcare User Manual BC720 ・ Enter gender Measurement ・ Select the gender, male or female using the touchpad. Basic analysis If you want to measure, stand on the device's scale. 1) Measure Weight ・ When you step on the scale, the screen changes with a chime bell, and the weight measurement starts.
  • Page 21: View Results

    SELVAS Healthcare User Manual BC720 6) Start measurement - measuring posture View results ・ Keep your arms and trunk at a 30° angle to avoid 1) Completing measurement and its result armpit contact. When the analysis is complete, the measurement results are displayed on the screen.
  • Page 22: Logging In And Taking Measurements With The Accuniq Connect App

    SELVAS Healthcare User Manual BC720 Logging in and taking measurements with the ACCUNIQ Connect app 3) Confirm that the information imported from the app is correct and proceed with the measurement. You can save your test results to your smartphone with this dedicated app for body composition measurement record keeping.
  • Page 23: Analysis Using A Blood Pressure Monitor

    SELVAS Healthcare User Manual BC720 RESULT SHEET INTERPRETATION Note When measuring height, if there is a taller person than the user around the device, accurate height measurement is not possible. When measuring height, make sure that no This device provides not only impedance measurement data, but also various analysis data such as body...
  • Page 24 SELVAS Healthcare User Manual BC720 Obesity Analysis Activity level Stable state Light activity Normal activity Heavy activity Extreme activity •Body Mass Index (BMI) Activity coefficient 1.375 1.55 1.725 Body Mass Index (BMI) is calculated as weight (kg) / height (m For an accurate obesity diagnosis, it is recommended to analyze not only the BMI, which considers only •Obesity Degree...
  • Page 25: Total Body Water Result Sheet

    SELVAS Healthcare User Manual BC720 •Visceral Fat Level (VFL) Total Body Water Result Sheet Subcutaneous fat and visceral fat are evaluated as appropriate when the ratio is 6:4, and the level is displayed by classifying the level of into 1 to 20 levels according to the ratio of visceral fat. Levels 1 to Total body water result sheet is a result sheet that provides analysis data related to body water.
  • Page 26: Result Sheet For Child (Option)

    SELVAS Healthcare User Manual BC720 Result sheet for child (Option) Obesity Analysis •Body Mass Index (BMI) Personal data Body Mass Index (BMI) is calcuated as weight (kg)/height (m User's name / ID number, measurement date, height, weight, age, and gender are printed.
  • Page 27: Storage And Maintenance

    Then, wipe the enclosure with a soft lint. Please refer to and abide by the “SAFETY PRECAUTIONS.” Caution Users must be sure to use sterile safety equipment such as gloves when in contact with or cleaning electrodes. SELVAS Healthcare is not responsible for safety accidents caused by users’ carelessness. _Result Sheet Interpretation Storage and Maintenance_...
  • Page 28: Problem Solving

    ・ Measurement range: 100~950Ω impedance by external influence. around equipment ・ If the same error is displayed on the LCD ・ Contact SELVAS Healthcare or distributor even during re-measurement, contact us or a designated vendor. ・ Out of measurement range of ・...
  • Page 29: Measurement Error Occurrence And Actions

    SELVAS Healthcare User Manual BC720 Measurement Error Occurrence and Actions Problems in use If there is a problem with the device, please follow the steps below: Error Cause Action 1) Please check again according to the measurement inspection items. If the problem persists, please contact us or a designated vendor.
  • Page 30: Specifications

    Explanation Result item [Result Sheet for Children (Option)] Model ACCUNIQ BC720 ・ Bocy Compositon Analysis: Weight, Fat Free Mass, Fat Mass, Soft Lean Mass, Measuring method BIA via tetra-polar electrode method using 8 touch electrodes Protein, Minerals, Total Body Water ・...
  • Page 31: Blood Pressure Monitor

    User Manual BC720 Blood Pressure Monitor List of supported printers This device can be connected to the below Automatic Blood Pressure Monitors from SELVAS Healthcare. Samsung SL-M2020, SL-M2026, SL-M2035, SL-M2035W, SL-M2620ND, SL-M3320ND, SL-C1810W, Brother HL-L2360DN, HL-L2365DW, HL-L2370DW, HL-L2375DW, HP M2030D2, 107W BP500 Depending on the region and whether the product is discontinued, the supported printers may vary slightly.
  • Page 32 Proper measurement Pass/Fail Other Clock Present date/time Pass/Fail General Judgment Pass/Fail General Judgment Pass/Fail Model ACCUNIQ BC720 Serial No. Model ACCUNIQ BC720 Serial No. Installation place Date of purchase Installation place Date of purchase Check date Checked by Approved by...
  • Page 33 SELVAS Healthcare, Inc. HEADQUARTERS 155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea Tel +82 42 879 3000 Fax +82 42 864 4462 When reporting a failure, check the user manual first, and after checking the problem, please inform us the model name, failure status, address, name, phone number, and location, and it would be convenient to know the affiliation and name of the recipient.